Chapter 4 Installation and Wiring
PAGE 4-30
4-6-2 PLC IO Signal (Multi System
:
:
:
:
Master)
IN: Input Signal
OUT: Output Signal
NC: Normal Close NO: Normal Open
Pin
Signal Name
IN/OUT
Function
・
・
・
・
Usage Instruction
1
IN COMMON
IN
Input signal common
(
Bi-directional
)
2
STOP
IN NC
Signal MUST be active to perform a fastening operation.
When this signal is inactive (off), all controller operation ceases, all
spindles in motion will stop and all communication ports & input/outputs
will be disabled.
3
RESET
IN NO
When active (on), this signal will clear all spindle data and discrete
outputs. A Zero Check of all load transducers will be completed. During
the Zero Check, the CHECK lamp will illuminate, the READY signal will
turn OFF, and the ACCEPT or REJECT lamp will light to indicate the
result of the Zero Check. If the System has been disabled by an
Abnormal output, the System will not return to normal operation until the
Abnormal condition has been corrected, and this signal has been input
for 200~500ms. Do not input this signal between cycles as part of an
automatic cycle due to the potential for spindle data loss.
4
REVERSE
IN NO
The selected spindle will move in the direction opposite of the tightening
direction for as long as this signal is activated (on) and maintained
5
START
IN NO
The Start input automatically resets the previous cycle, clears all data to
zero, and initiates the next fastening cycle.
6
BYPASS
IN NO
Spindle is ignored as if it does not exist as long as this signal is "ON"
7
SELF CHECK OFF
IN NO
When activated (ON) the Self Check of the torque transducer performed
at the start of the fastening operation will be disabled.
8
SEQ SELECT BIT 0
IN NO
These 5 inputs when selected in a binary code is capable of selecting
up to 32 different Sequences.
9
SEQ SELECT BIT 1
IN NO
10
SEQ SELECT BIT 2
IN NO
11
SEQ SELECT BIT 3
IN NO
12
SEQ SELECT BIT 4
IN NO
13
BANK SELECT
IN NO
Input bank selection (Changes definitions of output signals)
14
OUT COMMON
OUT
Output signal common
(
Bi-directional
)
15
OUT DATA 0
OUT NO
Outputs the system state depending on which BANK is selected.
(See bank Output signal definition on next page)
16
OUT DATA 1
OUT NO
17
OUT DATA 2
OUT NO
18
OUT DATA 3
OUT NO
19
OUT DATA 4
OUT NO
20
OUT DATA 5
OUT NO
21
OUT DATA 6
OUT NO
22
OUT DATA 7
OUT NO
23
OUT DATA 8
OUT NO
24
OUT DATA 9
OUT NO
25
OUT DATA 10
OUT NO
26
OUT DATA 11
OUT NO
・・・・
Be sure to set the BANK SELECT signal to OFF during the fastening operation or
when not required
・・・・
Output signal OUT DATA will be output approx. 20msec after a bank select input
has changed it
・・・・
When bank changing is executed, the definition of the output signals will be
changed.
Caution
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......