Chapter 5
I/O
Expansion Unit
Page 5-14
5-3-5 Description of Output Signals
ACCEPT: Fastening ACCEPT Signal TOTAL ACCEPT: Total ACCEPT Signal
REJECT: Fastening REJECT Signal TOTAL REJECT: Total REJECT Signal
ABNORMAL: System Error/Abnormal Exit
TOTAL ABNORMAL: Total System Error/Abnormal Exit
READY: Input Enabling Signal TOTAL READY: Total Input Enabling Signal
BUSY: Signal During Fastening TOTAL BUSY: Sequence-Operation-in-Progress Signal
DATA AVAILABLE: Fastening Result Data are Available
SPINDLE IN BYPASS: BYPASS Axis Detection Signal
PAR SELECT BIT 0 to 4: Parameter No. Return Signal (BIT)
SEQ SELECT BIT 0 to 4: Sequence No. Return Signal (BIT)
Please refer to “Description of Input and Output Signals” on Section 4-6 regarding the above
signals.
END: Fastening End Signal
Output when a fastening cycle is complete. Remains active until the START, RESET or REVERSE
signal is input. The signal is set
“ON” after the BUSY signal is set “OFF.”
The END signal also becomes “OFF” under the following conditions;
*At the start of CAL voltage check by the CAL switch of the MASTER spindle
CURRENT WARNING: Total Current Value Warning Signal
This signal is set “ON” when, any spindle peak current value during the fastening operation falls
outside the range of the fastening parameter D-
No. 522 “High Current Limit” or the fastening
parameter D-
No. 521 “Low Current Limit.”
CAL WARNING: Total CAL Voltage Warning Signal
This signal is set
“ON” if the CAL voltage of any spindle falls outside the allowable range during a
CAL voltage check (at the time of control power up or start of a fastening operation.)
ZERO LEVEL WARNING: Total ZERO Voltage Warning Signal
This signal is set
“ON” if the ZERO Level voltage of any spindle falls outside the allowable range
during a ZERO Level voltage check (at the time of control power up or start of a fastening operation.)
SEQ SELECT No. # (1 to 32): Sequence No. Return Signal (Individual)
Output confirmation of Individual SEQUENCE SELECT 1-32 input selections
.
ACCEPT No. # (1 to 32): ACCEPT Signal of Spindle 1-32
Output when the fastening result is a ACCEPT. Indicates that the spindle is within fastening limits.
This output remains active until the START signal or RESET signal is input.
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......