Chapter 5
I/O
Expansion Unit
Page 5-16
REVO. LO REJ. No. # (1 to 32): Rundown Revolution Low Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the rundown revolution is below the fastening parameter D-No.
503 “Rundown Revolution Low Limit.”
TQ. HI REJ. No. # (1 to 32): Torque High Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the peak torque (final torque) exceeds the fastening parameter
D-
No. 102 “Peak Torque High Limit” or the final torque exceeds the fastening parameter D-No. 119
“Final Torque High Limit.”
TQ. LO REJ. No. # (1 to 32): Torque Low Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the peak torque (final torque) is below the fastening parameter
D-
No. 101 “Peak Torque Low Limit” or the final torque is below the fastening parameter D-No. 118
“Final Torque Low Limit.”
FINAL ANG HI REJ. No. # (1 to 32): Final Angle High Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the final angle exceeds the fastening parameter D-No. 201
“Final Angle High Limit.”
FINAL ANG LO REJ. No. # (1 to 32): Final Angle Low Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the final angle is below the fastening parameter D-No. 200 “Final
Angle Low Limit.”
DifferANG REJ. No. # (1 to 32): Differ Angle Signal of Spindle 1-32
The signal is set “ON” if the value of the differential angle exceeds the fastening parameter D-No.
206 “Differ Angle.”
Differential -ANG REJ. No. # (1 to 32): Differential -Angle Signal of Spindle 1-32
The signal is set “ON” if the value of the differential angle is below the fastening parameter D-No. 207
“Differential - Angle.”
1st TIME HI REJ. No. # (1 to 32): 1st Time High Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the 1st Time at 1st torque or the 1st angle exceeds the fastening
parameter D-
No. 312 “1st Time High Limit.”
1st TIME LO REJ. No. # (1 to 32): 1st Time Low Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the 1st time at 1st torque or the 1st angle is below the fastening
parameter D-
No. 311 “1st Time Low Limit.”
2nd TIME HI REJ. No. # (1 to 32): 2nd Time High Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the 2nd time exceeds the fastening parameter D-No. 314 “2nd
Time High Limit.”
2nd TIME LO REJ. No. # (1 to 32): 2nd Time Low Limit Signal of Spindle 1-32
Th
e signal is set “ON” if the value of the 2nd time is below the fastening parameter D-No. 313 “2nd
Time Low Limit.”
RATE1 HI REJ. No. # (1 to 32): Rate 1 High Limit Signal of Spindle 1-32
The signal is set
“ON” if the value of rate 1 exceeds the fastening parameter D-No. 301 “Rate 1 High
Limit.”
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......