![FEC AFC3000 Скачать руководство пользователя страница 245](http://html.mh-extra.com/html/fec/afc3000/afc3000_hardware-operation-manual_547828245.webp)
Chapter 8 System Operation
PAGE 8- 38
[System Parameters – continued]
D-No. 312 IP Address (upper 6 digits)
D-No. 313 IP Address (lower 6 digits)
Setting range (each digit) : 0 to 255 (PROFINET IO, EtherNet/IP)
The IP address of the fieldbus set in the Controller is indicated.
D-No. 314 Subnet Mask (upper 6 digits)
D-No. 315 Subnet Mask (lower 6 digits)
Setting range (each digit): 0 to 255 (PROFINET IO, EtherNet/IP)
The subnet mask of the fieldbus set in the Controller is indicated.
D-No. 316 Gateway (upper 6 digits)
D-No. 317 Gateway (lower 6 digits)
Setting range (each digit): 0 to 255 (PROFINET IO, EtherNet/IP)
The gateway of the fieldbus set in the Controller is indicated.
D-No. 400 CF Card Storage Capacity [%]
The storable capacity of the CF card installed in the Expansion Unit 2 is indicated.
D-No. 401 Expansion RS232C-2 Communication Speed [bps]
The communication speed of the RS-232C-2 interface of the Expansion Unit 2 is indicated.
D-No. 402 Expansion RS232C-2 Parity
The parity of the RS-232C-2 interface of the Expansion Unit 2 is indicated.
D-No. 403 Expansion RS232C-2 Stop Bit [bit]
The stop bit of the RS-232C-2 interface of the Expansion Unit 2 is indicated.
D-No. 404 Expansion RS232C-2 Data Length [bit]
The data length of the RS-232C-2 interface of the Expansion Unit 2 is indicated.
D-No. 405 Expansion RS232C-3 Communication Speed [bps]
The communication speed of the RS-232C-3 interface of the Expansion Unit 2 is indicated.
D-No. 406 Expansion RS232C-3 Parity
The parity of the RS-232C-3 interface of the Expansion Unit 2 is indicated.
D-No. 407 Expansion RS232C-3 Stop Bit [bit]
The stop bit of the RS-232C-3 interface of the Expansion Unit 2 is indicated.
D-No. 408 Expansion RS232C-3 Data Length [bit]
The data length of the RS-232C-3 interface of the Expansion Unit 2 is indicated.
D-No. 500 Proface Display IP Address (upper 6 digits)
D-No. 501 IP Address (lower 6 digits)
Setting range (each digit) : 0 to 255 (Ex. upper digit: 192.168) (Ex. lower digit: 11.200)
The ethernet IP address of a Proface remote display connected to the controller is set / indicated.
D-No. 502 Proface Display Language Select [bit]
Setting Range: None, 1 or 2
None: Disabled 1:Japanese 2:English
NOTE: Disable if Proface remote display is not being used. If turned on (“1” or “2”) the controller
will continue to ‘ping’ the Ethernet TCP/IP port attempting to connect to the Proface unit until
connection is made. This may be seen by monitoring devices on the Ethernet line as an
‘intrusion’ or ‘nuisance’.
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......