253
Detector III
Select
Condition monitoring
>
New
position
.
Then go to
Select template
to choose a suitable template. You can select the
template of a previous measurement, alternatively.
In the next menu you can change the template name so that the free
measurement can later be assigned to the measuring point at which it was
recorded.
o
If you accept the name without changing it, the free measurement is assigned
the template name and also a reference number that increases by one each
time a new measurement is taken using this template (<Name> 1, <Name> 2,
...).
o
To change the name select
Change name
and confirm your choice with the
Enter button
. On the next screen, the name of the template selected and the
current order number are displayed, and a cursor is positioned under the first
letter. Change the name as described in Key pad entries
.
After changing the name select
Continue
.
Select
Settings
to adopt the configuration of the template.
When carrying out a free measurement all other values can be changed in
addition to the template name. To do this, select the
Settings
item in the menu.
You can now select the relevant values using the Enter button
. Depending on
the type of setting, you can now type in a new value directly, make a selection from
a drop-down menu or modify an item of text as described above. Leave the
settings menu with the Esc button
.
Select
Start measurement
to begin the measuring procedure.
From this point onwards the sequence of the measuring process is identical to
the Standard measurement
process (initialization of hardware, recording of
characteristic values, display of measuring results with comment selection,
storage of measured data).