16
A/D converter
16-bit (auto ranging)
Dy namic range >90 db
Frequency resolution
1600, 3200 lines (0.0625 Hz up to 12.5 Hz depending on the
configured low pass frequency )
Balancing
1 or 2 plane balancing
Weight positions: continuous (0 to 359°) or discrete (4 to 99
positions)
Remov e trial w eights: y es/no
Balancing measurement type
Acceleration, v elocity , displacement
Measurement
Peak, Peak – Peak, RMS
Balancing units
g, mm/s, inch/s, µm, mil
Weights units
g, oz (up to 99 999,99 g / oz)
Automatic measuring point detection (RFID)
Radio frequency
13.65 MHz
RFID standard
ISO 15693
Product must only be operated
in
European Union (EU), Sw itzerland, USA, Canada, Australia
General
Separate measurements
Temperature, rotational speed, headset (env elope signal)
Keyboard
Membrane key board w ith 21 key s
Display
Backlit graphic display (LCD) 128x 64 pix els,
dimension 55 x 33 mm
Memory
1600 measuring points plus 270 time signals (max imal 300 time
signals)
Power supply
NiMh 2 000 mAh
Voltage 6V
Operation time approx . 6 to 8 hours (charging time for empty battery
approx . 4 h)
Size and weight
230 x 70 (53) x 45 (53) mm (L x W x H), approx . 500 g (including
battery )
Temperature range
0 to 50 °C (operating temperature)
0 to 40°C (to load the charger)
-20 to +70 °C (storage and transport temperature)
Operation time
approx . 6 to 8 hours continuous operation