configure sys-health-check auto-recovery
ExtremeWare Software 7.3.0 Command Reference Guide
651
configure sys-health-check auto-recovery
configure sys-health-check auto-recovery <number> [offline | online] |
alarm-level [card-down | default | log | system-down | traps]
Description
Configures the system health checker.
Syntax Description
Default
Log.
Usage Guidelines
This command allows you to configure the switch’s reaction to a failed health check.
The system health checker tests I/O modules, MSM modules, and the backplane by forwarding packets
every 4 seconds. Additional checking for the validity of these packets is completed by performing a
checksum.
By isolating faults to a specific module, MSM, or backplane connection, the system health checker
prevents corrupted packets from being propagated to the CPU, upper layer modules, or the rest of your
network. If you observe a failure, please contact Extreme Technical Support.
Depending on how you have configured the system health checker, failed system health checks may
generate critical error messages in the syslog, and may also send a trap and/or shut down the system.
The system health checker will continue to periodically forward test packets to failed components. If
auto-recovery is configured, the system will attempt to automatically reset the faulty module and bring
it back online.
number
Specifies the number of times that the health checker attempts to auto-recover
a faulty module. The range is from 0 through 255 times. Default is 3 times.
Applies only to BlackDiamond I/O modules.
offline
Specifies that a faulty module is taken offline and kept offline if one of the
following occurs:
•
More than eight defects are detected.
•
Three consecutive checksum errors were detected by the health checker,
but no new defects were found by the memory scanning and mapping
process.
•
After defects were detected and mapped out, the same checksum errors
are again detected by the system health checker.
online
Specifies that a faulty module is kept online, regardless of memory scanning
or memory mapping errors.
card-down
Posts a CRIT message to the log and brings the module down.
default
Resets the alarm level to log.
log
Posts a CRIT message to the log.
system-down
Posts a CRIT message to the log, sends a trap, and turns off the system.
traps
Posts a CRIT message to the log and sends a trap.
Содержание ExtremeWare 7.3.0
Страница 54: ...54 ExtremeWare Software 7 3 0 Command Reference Guide Contents...
Страница 104: ...104 ExtremeWare Software 7 3 0 Command Reference Guide Commands for Accessing the Switch...
Страница 378: ...378 ExtremeWare Software 7 3 0 Command Reference Guide FDB Commands...
Страница 418: ...418 ExtremeWare Software 7 3 0 Command Reference Guide QoS Commands...
Страница 436: ...436 ExtremeWare Software 7 3 0 Command Reference Guide NAT Commands...
Страница 600: ...600 ExtremeWare Software 7 3 0 Command Reference Guide SLB Commands...
Страница 968: ...968 ExtremeWare Software 7 3 0 Command Reference Guide Security Commands...
Страница 1002: ...1002 ExtremeWare Software 7 3 0 Command Reference Guide EAPS Commands...
Страница 1126: ...1126 ExtremeWare Software 7 3 0 Command Reference Guide ESRP Commands...
Страница 1392: ...1392 ExtremeWare Software 7 3 0 Command Reference Guide IGP Commands...
Страница 1478: ...1478 ExtremeWare Software 7 3 0 Command Reference Guide BGP Commands...
Страница 1556: ...1556 ExtremeWare Software 7 3 0 Command Reference Guide IP Multicast Commands...
Страница 1600: ...1600 ExtremeWare Software 7 3 0 Command Reference Guide IPX Commands...
Страница 1616: ...1616 ExtremeWare Software 7 3 0 Command Reference Guide ARM Commands...
Страница 1694: ...1694 ExtremeWare Software 7 3 0 Command Reference Guide PoS Commands...
Страница 1750: ...1750 ExtremeWare Software 7 3 0 Command Reference Guide T1 E1 and T3 WAN Commands...
Страница 1856: ...1856 ExtremeWare Software 7 3 0 Command Reference Guide MPLS Commands...
Страница 1898: ...1898 ExtremeWare Software 7 3 0 Command Reference Guide High Density Gigabit Ethernet Commands...
Страница 1938: ...1938 ExtremeWare Software 7 3 0 Command Reference Guide Power Over Ethernet Commands...
Страница 1988: ...1988 ExtremeWare Software 7 3 0 Command Reference Guide H VPLS Commands...
Страница 2106: ...2106 ExtremeWare Software 7 3 0 Command Reference Guide Wireless Commands...
Страница 2132: ...2132 ExtremeWare Software 7 3 0 Command Reference Guide Configuration and Image Commands...
Страница 2236: ...2236 ExtremeWare Software 7 3 0 Command Reference Guide Troubleshooting Commands...
Страница 2254: ...2254 ExtremeWare Software 7 3 0 Command Reference Guide Index of Commands...