CPRI/OBSAI Test Setup and Results
234
FTB-860/880
Global Configuration
The Global Pass/Fail verdict is declared as Fail when at least one of the
following errors is raised during the test:
Bit Error
Symbol Error
RTD Calibration Failed
BER Threshold
: If the Pass/Fail verdict is enabled, select the threshold
amount as follows:
If the
Pass/Fail Verdict
is
Bit Error Count
, the accepted
BER
Threshold
range is
0
to
999999
with default value of
0
. The
BER
Threshold
indicates the number of accepted errors before the test
is declared as Fail.
If the
Pass/Fail Verdict
is
Bit Error Rate
, the accepted
BER
threshold
range is
1.0E-14
to
1.9E-01
with default value of
1.0E-12
. The
BER Threshold
indicates the accepted Bit error rate
before the test is declared as Fail.