![Esco invt GD350A Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081081.webp)
GD350A series high-performance multifunction VFD
-76-
Function
code
Name
Description
Default
7: Profibus/CANopen/DeviceNet communication
(same as the above)
8: Ethernet communication (same as the above)
9: Pulse frequency HDIB (same as the above)
10: EtherCat/Profinet/EtherNetIP communication
11: Programmable expansion card
12: Reserved
Note:
For setting methods 1–11, 100% corresponds
to the maximum frequency.
Setting source of
reverse rotation
upper-limit
frequency in
torque control
0: Keypad (P03.17)
1: AI1 (100% corresponding to the max. frequency)
2: AI2 (same as the above)
3: AI3 (same as the above)
4: Pulse frequency HDIA (same as the above)
5: Multi-step setting (same as the above)
6: Modbus/Modbus TCP communication (same as
the above)
7: Profibus/CANopen/DeviceNet communication
(same as the above)
8: Ethernet communication (same as the above)
9: Pulse frequency HDIB (same as the above)
10: EtherCat/Profinet/EtherNetIP communication
11: Programmable expansion card
12: Reserved
Note:
For setting methods 1–11, 100% corresponds
to the maximum frequency.
0
Forward rotation
upper-limit
frequency set
through keypad
in torque control
0.00Hz–P00.03 (Max. output frequency)
50.00 Hz
Reverse rotation
upper-limit
frequency set
through keypad
in torque control
0.00Hz–P00.03 (Max. output frequency)
50.00 Hz
Setting source of
electromotive
0: Keypad (P03.20)
1: AI1 (100% corresponding to three times the
0