![Esco invt GD350A Series Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081075.webp)
GD350A series high-performance multifunction VFD
-70-
Function
code
Name
Description
Default
of motor 2
V/F frequency
point 2 of motor 2
0.00Hz
V/F voltage point 2
of motor 2
0.0%–110.0%
0.0%
V/F frequency
point 3 of motor 2
P04.18– P02.02 or P04.18– P02.16
0.00Hz
V/F voltage point 3
of motor 2
0.0%–110.0%
0.0%
V/F slip
compensation gain
of motor 2
0.0–200.0%
100.0%
Low-frequency
oscillation control
factor of motor 2
0–100
10
High-frequency
oscillation control
factor of motor 2
0–100
10
Oscillation control
threshold of motor
2
0.00Hz–P00.03 (Max. output frequency)
30.00Hz
Energy-saving run
0: Disable
1: Automatic energy-saving run
0
Voltage setting
channel
0: Keypad; Output voltage is determined by
P04.28
1: AI1
2: AI2
3: AI3
4: HDIA
5: Multi-step running
6: PID
7: Modbus/Modbus TCP communication
8: Profibus/CANopen/DeviceNet
communication
9: Ethernet communication
10: HDIB
11: EtherCat/Profinet/EtherNetIP
0