Function
code
Name
Description
Default
SM 1
depended
Direct-axis inductance
of SM 1
0.01–655.35mH
Model
depended
Quadrature-axis
inductance of SM 1
0.01–655.35mH
Model
depended
Counter-emf constant
of SM 1
0–10000
300
Function selection of
multifunction digital
input terminals (S1–
S4, HDIA, HDIB)
35: Switch from motor 1 to motor 2
Switching between
motor 1 and motor 2
0x00–0x14
Ones place: Switchover channel
0: Terminal
1: Modbus/Modbus TCP communication
2: Profibus/CANopen/DeviceNet
communication
3: Ethernet communication
4: EtherCat/Profinet/EtherNetIP
communication
Tens place: indicates whether to enable
switchover during running
0: Disable
1: Enable
00
Type of motor 2
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
Rated power of AM 2 0.1–3000.0kW
Model
depended
Rated frequency of
AM 2
0.01Hz–P00.03 (Max. output frequency)
50.00Hz