GD350A series high-performance multifunction VFD
-181-
Function
code
Name
Description
Default Modify
24: Set frequency (bipolar, 0–Max. output
frequency)
25: Ramp reference frequency (bipolar, 0–
Max. output frequency)
26: Rotational speed (bipolar, 0–Speed
corresponding to max. output frequency)
27: Value 2
set through
EtherCat/Profinet/EtherNetIP (0–1000)
28: C_AO1 (Set P27.00 to 1. 0–1000)
29: C_AO2 (Set P27.00 to 1. 0–1000)
30: Rotational speed (0–Twice the motor rated
synchronous speed)
31: Output torque (Actual value, 0–Twice the
motor rated torque)
32–47: Reserved
P06.17
AO1 output lower
limit
The function codes define the relationship
between the output value and analog output.
When the output value exceeds the allowed
range, the output uses the lower limit or upper
limit.
When the analog output is current output, 1mA
equals 0.5V.
In different cases, the corresponding analog
output of 100% of the output value is different.
See each application for detailed information.
10V (20mA)
0.0%
100.0%
AO
Setting range of P06.17: -300.0%–P06.19
Setting range of P06.18: 0.00V–10.00V
Setting range of P06.19: P06.17–300.0%
Setting range of P06.20: 0.00V–10.00V
Setting range of P06.21: 0.000s–10.000s
0.0%
○
P06.18
AO1 output
corresponding to
lower limit
0.00V
○
P06.19
AO1 output upper
limit
100.0%
○
P06.20
AO1 output
corresponding to
upper limit
10.00V
○
P06.21
AO1 output filter
time
0.000s
○
P06.22–
Reserved
0–65535
0
●