![Esco invt GD350A Series Скачать руководство пользователя страница 247](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081247.webp)
GD350A series high-performance multifunction VFD
-242-
Function
code
Name
Description
Default Modify
between encoder
mounting shaft and
motor
encoder is not installed on the motor shaft
and the drive ratio is not 1.
Setting range: 0.001–65.535
P24.07
Control parameters
of SM
Bit0: Enable Z pulse calibration
Bit1: Enable encoder angle calibration
Bit2: Enable SVC speed measurement
Bit3: Reserved
Bit4: Reserved
Bit5: Reserved
Bit6: Enable CD signal calibration
Bit7: Reserved
Bit8: Do not detect encoder fault during
autotuning
Bit9: Enable Z pulse detection optimization
Bit10: Enable initial Z pulse calibration
optimization
Bit12: Clear Z pulse arrival signal after stop
0x3
○
P24.08
Enabling Z pulse
offline detection
0x00–0x11
Ones place: Z pulse
0: Do not detect
1: Enable
Tens place: UVW pulse (for SM)
0: Do not detect
1: Enable
0x10
○
P24.09
Initial angle of Z
pulse
Relative electric angle of encoder Z pulse and
motor pole position.
Setting range: 0.00–359.99
0.00
○
P24.10
Initial angle of the
pole
Relative electric angle of encoder position and
motor pole position.
Setting range: 0.00–359.99
0.00
○
P24.11
Autotuning of initial
angle of pole
0–3
1: Rotary autotuning (DC brake)
2: Static autotuning (suitable for resolver-type
encoder, sin/cos with CD signal feedback)
3: Rotary autotuning (initial angle
identification)
0
◎
P24.12
Speed
0: No optimization
1
◎