GD350A series high-performance multifunction VFD
-115-
Digital output 16
Simple PLC state completed
Digital output 17
Simple PLC cycle completed
Related parameter list:
Function
code
Name
Description
Default
Digital input function
selection
23: Simple PLC stop reset
24: Pause simple PLC
25: Pause PID control
Digital output function
selection
16: Simple PLC stage reached
17: Simple PLC cycle reached
Simple PLC mode
0: Stop after running once
1: Keep running in the final value after
running once
2: Cyclic running
0
Simple PLC memory
selection
0: No memory after power off
1: Memory after power off
0
Multi-step speed 0
-100.0–100.0%
0.0%
Running time of step 0
0.0–6553.5s (min)
0.0s
Multi-step speed 1
-100.0–100.0%
0.0%
Running time of step 1
0.0–6553.5s (min)
0.0s
Multi-step speed 2
-100.0–100.0%
0.0%
Running time of step 2
0.0–6553.5s (min)
0.0s
Multi-step speed 3
-100.0–100.0%
0.0%
Running time of step 3
0.0–6553.5s (min)
0.0s
Multi-step speed 4
-100.0–100.0%
0.0%
Running time of step 4
0.0–6553.5s (min)
0.0s
Multi-step speed 5
-100.0–100.0%
0.0%
Running time of step 5
0.0–6553.5s (min)
0.0s
Multi-step speed 6
-100.0–100.0%
0.0%
Running time of step 6
0.0–6553.5s (min)
0.0s
Multi-step speed 7
-100.0–100.0%
0.0%
Running time of step 7
0.0–6553.5s (min)
0.0s
Multi-step speed 8
-100.0–100.0%
0.0%