Figure 3-82: Shroud security seals
A. Top end shroud
B. Security wire seals
Procedure
1. Install the security seal wire into and through the two bolt holes on the top end
shrouds (maximum wire diameter .078 inch; 2.0 mm). Position the wire to prevent
counterclockwise rotation of the screws when the seal wire is taut.
2. Remove all slack and seal.
3. Repeat previous step for the other top end shroud.
4. Cut wire ends to remove excess wire.
This completes the clamped band shroud security seal installation procedure.