Figure 3-79: Base Enclosure security seals
A. Base Enclosure
B. Security wire seals
2. Position the wire to prevent counterclockwise rotation of the screws when the seal
wire is taut.
3. Twist and adjust wire removing all slack and seal.
4. Cut wire ends to remove excess wire.
3.11.3
Seal the Junction Box for remote mount electronics
option
Use the following instructions to install the security seal wire on the junction box, if
required.
Procedure
1. Install security wire seal into and through two of the four the holes in the socket
head screws on the Junction Box cover (maximum wire diameter .078 inch; 2.0
mm).