Error Reporting
375
Error Code
(hex)
Response Description
Error Type Possible Cause
axes but greater than the number of axes
that are NOT already executing programs.
72
Status Only
Execute multi-axis program
with multi-axis program
already active
Module
An Execute Program Q bit was set for a
multi-axis program when a multi-axis
program was already executing.
Note:
Error 0075 will be reported instead of
Error 0072 if the DSM is configured
for only 1 axis. Error 0071 will be
reported instead of Error 0072 if the
DSM is configured for only 2 axes.
73
Status Only
Execute Program for axis
configured as Limited Aux
axis
Module
Motion Programs cannot be executed on an
axis configured as Limited Aux. A Limited
Aux axis performs position feedback
processing only and does not have an
internal motion path generator.
74
Reserved - not used in
DSM314
75
Status Only
Empty or Invalid Program
requested
Module
An Execute Program Q bit was set for a
program number not defined in the
configured motion program block.
This error is also reported if the DSM is
configured for fewer axes than the axis
number of the requested program. Check
the configuration for a correct motion
program block name. Make sure the
requested program number is defined in the
configured program block. Make sure the
DSM is configured for a number of axes
greater than or equal to the axis number of
the requested program.
76
Status Only
AQ Move Command Position
Out of Range
Axis
The user sent an AQ Move command (27h)
with a position value greater then the
maximum position range.
(-536,870,912 to +536,870,911 at 1:1
scaling)
77
Status Only
AQ move command on first
PLC sweep
Axis
An AQ Move command (27h) was
commanded on the first PLC sweep. The PLC
program must be corrected to prevent AQ
Move commands from being sent on the
first sweep.
Program Execution Conditions Errors
80
Status Only
Execute Program while Home
Cycle active
Axis
The PLC set an Execute Program Q bit while
the module was executing a home cycle.
The user either needs to wait until the home