User Manual
Appendix A
GFK-1742F
Jan 2020
Error Reporting
372
Error Code
(hex)
Response Description
Error Type Possible Cause
halted (Program Active I bit off) prior to
executing the Set Position command.
51
Status Only
Set Position Data over-range
error
Axis
The user executed a Set Position command
with a value greater then the maximum
position range (-536,870,912 to
+536,870,911 at 1:1 scaling)
52
Status Only
Set Position while Moving or
Set Position while not
Moving, not In Zone and
velocity > 100 cts/sec.
Axis
Set Position is not allowed if the Moving %I
bit is on. If the Moving bit is off and the In
Zone %I bit is also off, the Actual Velocity
must be < 100 cts/second.
53
Status Only
Attempt to initialize position
before digital encoder passes
reference point.
Axis
The absolute digital encoder was not
rotated past the zero reference point after
the first application of power. The encoder
must be rotated past the reference point (up
to 1 revolution) before Set Position is
allowed in absolute mode.
54
Status Only
Digital encoder position
invalid, must use Find Home
or Set Position.
Axis
1. Absolute encoder position has not been
initialized since first application of
power
2. Configuration for Encoder mode has
been changed from incremental to
absolute.
3. Configuration for Axis Direction
(normal or reverse) has been changed.
4. Encoder resolution (Set with Advanced
configuration tab parameter) has been
changed.
5. Encoder alarm has occurred
55
Status Only
Digital Encoder moved too far
while power off
Axis
The digital absolute encoder was moved
more than 16,383 revolutions while power
was off.
End of Travel and Count Limit Errors
56
Status Only
Commanded Position >
Positive End of Travel or High
Count Limit
Axis
The user executed a command that resulted
in the Commanded Servo Position
exceeding the Positive End of Travel or High
Count Limit. Either fix the command to be
less than these values or make the values
higher in Hardware Configuration.
57
Status Only
Commanded Position <
Negative End of Travel or Low
Count Limit
Axis
The user executed a command that resulted
in the Commanded Servo Position
exceeding the Negative End of Travel or Low
Count Limit. Either fix the command to be
greater than these values or make the values
more negative in Hardware Configuration