User Manual
Chapter 13
GFK-1742F
Jan 2020
Local Logic Variables
316
Table 67: Axis 3 Variables
Local Logic Variable Name
Attribute
Size
FacePlate I/O
Strobe1_Level_3
Read Only
Bit Operand
Strobe2_Level_3
Read Only
Bit Operand
Positive_EOT_3
Read Only
Bit Operand
Negative_EOT_3
Read Only
Bit Operand
Home_Switch_3
Read Only
Bit Operand
Digital_Output1_3 *
Write Only
Bit Operand
Digital_Output3_3 *
Write Only
Bit Operand
Analog_Input1_3
Read Only
Signed 16 Bits
Analog_Input2_3
Read Only
Signed 16 Bits
Control Variables
Reset_Strobe1_3
Write Only
Bit Operand
Reset_Strobe2_3
Write Only
Bit Operand
Status Variables
Error_Code_3
Read Only
Unsigned 16 Bits
Actual_Position_3
Read Only
32 Bits
Strobe1_Position_3
Read Only
32 Bits
Strobe2_Position_3
Read Only
32 Bits
Actual_Velocity_3
Read Only
32 Bits
Axis_OK_3
Read Only
Bit Operand
Position_Valid_3
Read Only
Bit Operand
Strobe1_Flag_3
Read Only
Bit Operand
Strobe2_Flag_3
Read Only
Bit Operand
*
These Digital Outputs must be configured for Local Logic control in Hardware Configuration
in order to be write-able by Local Logic.
Note:
For Axis 3, the DSM314 Version 2.0 only supports the variables in Table 67.