User Manual
Chapter 4
GFK-1742F
Jan 2020
Configuration
103
1.04 Local Logic Mode. This parameter defines the Local Logic engine status. To enable
Local Logic this parameter must be set to Enabled. If Local Logic is enabled, the
maximum number of Servo axes available is 3. A Local Logic Block Name must also
be entered when Local Logic Mode = Enabled. (Default = Disabled)
1.05 Total Encoder Power. This parameter defines the total power consumption for all
encoders attached to the DSM module. (Default = 0). This parameter should account
for all analog axis and master encoders and is used to update the Power
Consumption display in the configuration software.
1.06 Motion Program Block Name. This parameter defines the optional Motion Program
block name to execute on the DSM module. If no name is entered, the DSM will
assume that Motion Program blocks are not used. If a name is entered, a Motion
Program block of the same name must exist within the active folder. Entering an
invalid name will cause an error to be generated when storing the hardware
configuration to the PLC. The name may consist of up to 31 characters, but cannot
have any blank spaces, although you are allowed to use the underline character.
Both upper- and lower-case characters are permitted. (Default = <blank>).
1.07 Local Logic Block Name. This parameter defines the optional Local Logic block name
to execute on the DSM module. If no name is entered, the DSM will assume that
Local Logic blocks are not used. If a name is entered, a Local Logic block of the same
name must exist within the active folder. Entering an invalid name will cause an error
to be generated when storing the hardware configuration to the PLC. The name may
consist of up to 31 characters, but cannot have any blank spaces, although you are
allowed to use the underline character. Both upper- and lower-case characters are
permitted. For Local Logic to operate, the Local Logic Mode must also be set to
Enabled. (Default = <blank>).
1.08 CAM Block Name. Defines the optional CAM block name to execute on the DSM
module. If no name is entered, the DSM will assume that CAM blocks are not used.
If a name is entered, a CAM block of the same name must exist within the active
folder. Entering an invalid name will cause an error to be generated when storing the
hardware configuration to the PLC. The rules for CAM Block names are:
•
Only the characters A-Z, a-z, 0-9, and _ (underscore symbol) are allowed.
Consecutive underscores and blank spaces are not allowed.
•
The CAM block name must begin with a letter or underscore symbol.
•
A block cannot have the same name as another block that exists in an open folder.
•
A CAM block name may contain up to a maximum of seven characters.
•
This feature was first supported in DSM314 firmware release 2.00.
See Chapter 15 for CAM feature details. (Default = <blank>).
1.09 I/O Scan Set.
The scan set (as defined in the CPU's Scan Sets tab) to be assigned to this module.
For details on scan set operation refer to the PACSystems CPU Reference Manual,
GFK-2222.