User Manual
Chapter 7
GFK-1742F
Jan 2020
Programmed Motion
195
Example 2: Changing the Acceleration Mode During a Profile
The following example shows how a different acceleration, and an even acceleration mode,
can be used during a profile using CMOVEs. The first CMOVE accelerates linearly to the
programmed velocity. Because the
second CMOVE’s velocity is identical to the first,
the first
CMOVE finishes its move without changing velocity. The acceleration of the second move is
S-curve as it decelerates to zero velocity.
Figure 74: Changing the Acceleration Mode During a Profile
Example 3: Not Enough Distance to Reach Programmed Velocity
CMOVES and PMOVES can be programmed that do not have enough distance to reach the
programmed velocity. The following graph shows a CMOVE that could not reach the
programmed velocity. The DSM314 accelerates to the point where it must start
decelerating to reach the programmed position of C1 at the velocity of the second
CMOVE.
Figure 75: Not Enough Distance to Reach Programmed Velocity