29
Installation Procedures
Installation
IND100078-38
Access to Power Cable Input (Table model)
The Chart & Planning Table requires 115&230VAC (50/60Hz) power input and the power cable needs to be connected via the
Junction Box/Screw Terminal internally. It is assumed that the incoming power cable comes through the floor. Make sure the Chart
& Planning Table (hereby referenced as Unit) is powered off (by the 0/1 switch in front) before installation.
Note: Illustrations below may deviate slightly from written instructions (based on how the unit was delivered/tested prior to actual
installation onboard occurs). All procedures should be performed by a skilled technician that can interpret the physical parts and
correctly identify them on the illustrations below for correct installation).
▼1: The Main Power Input junction box is located inside the
Floor stand in the bottom as indicated below.
▼2: Indicates where cables should enter (through floor).
▼3: Remove the Top Foot Covers first as indicated. 4 screws on
both sides.
▼4: Remove the Bottom Foot Covers first as indicated. 6 screws on
both sides.
▼5: Depending on factory configuration, there may be an
internal HT C02 computer installed or not. If present, remove it
as illustrated. If there is no computer present, proceed directly to
Step 6. Loosen and remove 6 screws as indicated, and
disconnect ALL cables from computer before sliding it sideways
to reveal Power Junction Box underneath.
▼6: Location and connection close-up of Junction Box to connect
main power cable. When done, follow the Steps here in reverse to
mount all parts removed again. The illustration below should be
viewed in color!
Junction Box is seen from top (users point-of-view).
Grounding Screw
Exit Cable to unit
Entry (your) cable
Содержание Hatteland X Series
Страница 8: ...8 This page left intentionally blank...
Страница 9: ...9 General...
Страница 17: ...17 Installation...
Страница 35: ...35 Maintenance...
Страница 47: ...47 Operation...
Страница 83: ...83 Operation Advanced DDC CI...
Страница 87: ...87 Specifications...
Страница 98: ...98 This page left intentionally blank...
Страница 99: ...99 Technical Drawings...
Страница 101: ...101 IND100132 281 Technical Drawings HD 55T22 MVD MA1 TxGx Cable Openings...
Страница 111: ...111 Technical Drawings Accessories...
Страница 116: ...116 This page left intentionally blank...
Страница 117: ...117 Appendixes...
Страница 131: ...131 Appendix IND100077 24 User Notes...
Страница 133: ...133 Revision History Appendix IND100077 161...
Страница 134: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...