19
General Installation Recommendations
Installation
IND100078-41
3. The 55 inch units in particular are tested and approved for horizontal (table/desk) mount and vertical (wall) mount
using our brackets. Please consider the thermal situation when mounting the unit, in particular when mounted flat.
"Air traps" must be avoided, active ventilation might be required, depending on the actual installation.
LCD Panel
Chart & Planning Table - Thermal Solution
Air escapes
through all 4 sides
of top chassis
Air flow from
vents inside
chassis
Fresh air intake
through ventilation openings
Desktop/Wall Flat Mount - Thermal Solution
LCD Panel
Table Top / Wall
Hot air needs to escape when mounted.
Thermally controlled fans are suggested as the optimal solution.
Console Flat Mount - Thermal Solution
Hot air needs to escape/circulate the console casing.
Thermally controlled fans are suggested as the optimal solution.
Table/Panel
LCD Panel
Smaller sized units (<55 inch, example 32 inch) must generally be installed in a vertical position (±30 degrees) to
improve airflow through the unit as opposed to mounting them in a horizontal position (laying down) which will cause
heat to build up inside the unit (air traps) - which will damage the internal LCD Panel during long term use.
4. To further improve the thermal situation we recommend using forced air passing by the product. In some cases,
convection based cooling can create “heat zones” around the product. This may be required in high temperature
applications and also when there is reason to expect temperature problems due to non-optimal way of mounting.
5. Exposure to extreme direct sunlight can cause a considerable increase in the temperature of the unit, and might
under certain circumstances lead to excesssive temperature. This point should already be taken into consideration
when the bridge equipment is being planned (sun shades, distance from the windows, ventilation, etc.)
6. Space necessary for ventilation, for cable inlets, for the operating procedures and for maintenance, must be
provided.
7. If the push buttons of the product are not illuminated, an external, dimmable illumination (IEC 60945 Ed. 4, 4.2.2.3,
e.g. Goose neck light) is required for navigational use. The illumination should be free from glare and adjustable to
extinction.
8. Information about necessary pull-relievers for cables is indicated in the Physical Connection section of this manual.
Attention must be paid to this information so that cable breaks will not occur, e.g. during service work.
9. Do not paint the product. The surface treatment influences the excess heat transfer. Painting, labels or other
surface treatments that differ from the factory default, might cause overheating.
10. Exposure to heavy vibration and acoustic noise might under certain circumstances affect functionality and expected
lifetime. This must be considered during system assembly and installation. Mounting position must be carefully
selected to avoid any exposure of amplified vibration.
Содержание Hatteland X Series
Страница 8: ...8 This page left intentionally blank...
Страница 9: ...9 General...
Страница 17: ...17 Installation...
Страница 35: ...35 Maintenance...
Страница 47: ...47 Operation...
Страница 83: ...83 Operation Advanced DDC CI...
Страница 87: ...87 Specifications...
Страница 98: ...98 This page left intentionally blank...
Страница 99: ...99 Technical Drawings...
Страница 101: ...101 IND100132 281 Technical Drawings HD 55T22 MVD MA1 TxGx Cable Openings...
Страница 111: ...111 Technical Drawings Accessories...
Страница 116: ...116 This page left intentionally blank...
Страница 117: ...117 Appendixes...
Страница 131: ...131 Appendix IND100077 24 User Notes...
Страница 133: ...133 Revision History Appendix IND100077 161...