86
Operation Advanced (DDC/CI) Control Overview
IND100064-52
Description
Syntax and Functionality
Details and Values
Via SCOM
Touch Power Mode
(0xE6)
Write/Set Power Mode:
[S] <6E:w>
51 84 03
E6
00
xx
A1
[P]
Reply of successfull request:
[S] <6F:r>
5C 80 BE
*[P]
Read Power Mode:
[S] <6E:w>
51 82 01
E6
5A
[P]
Reply of successfull request :
[S] <6F:r>
6E 88 02 00
E6
01 00 FF 00
FF
53
*[P]
E6
= Command ID
Where
xx
is:
0x
FF
= Always Active
0x
FE
= Only active when display is
on and has an active input
signal
0x
00
= Only active if selected source
is active AND Selected
Source="DVI-I_1"*
0x
01
= Only active if selected source
is active AND Selected
Source="DVI-I_2"*
0x
02
= Only active if selected source
is active AND Selected
Source="DVI3"*
0x
03
= Only active if selected source
is active AND Selected
Source="DVI4"*
0x
10
= Only active if selected source
is active AND Selected
Source="RGB_1"*
0x
11
= Only active if selected source
is active AND Selected
Source="RGB_2"*
0x
12
= Only active if selected source
is active AND Selected
Source="RGB_3"*
0x
13
= Only active if selected source
is active AND Selected
Source="RGB_4"*
0x
20
= Only active if selected source
is active AND Selected
Source="CVIDEO1"
0x
21
= Only active if selected source
is active AND Selected
Source="CVIDEO2"
0x
22
= Only active if selected source
is active AND Selected
Source="CVIDEO3"
0x
23
= Only active if selected source
is active AND Selected
Source="CVIDEO4"
0x
30
= Only active if selected source
is active AND Selected
Source="DP1"
0x
31
= Only active if selected source
is active AND Selected
Source="DP2"
0x
32
= Only active if selected source
is active AND Selected
Source="DP3"
0x
33
= Only active if selected source
is active AND Selected
Source="DP4"
0x
3F
= Read Command
Read/Write support.
MCC:
(Touch Power
Mode)
Actual Temperature
(0xF0)
Read Temperature:
[S] <6E:w>
51 82 01
F0
4C
[P]
Reply of successfull request:
[S] <6F:r>
6E 88 02 00
F0
01
ww xx yy zz
63
*[P]
F0
= Command ID
Read support.
Reply 4 bytes (
ww, xx, yy, zz
)
indicating degree in Celcius.
Example: 0038
TMP
Unit Run Time
(0xF3)
Read Elapsed Hours:
[S] <6E:w>
51 82 01
F3
4F
[P]
Reply of successfull request:
[S] <6F:r>
6E 88 02 00
F3
01
ww xx yy zz
63
*[P]
F3
= Command ID
Read support.
Reply in ASCII 4 bytes
(
ww, xx, yy, zz
) indicating hours.
Example: 1038
ETC
Содержание Hatteland X Series
Страница 8: ...8 This page left intentionally blank...
Страница 9: ...9 General...
Страница 17: ...17 Installation...
Страница 35: ...35 Maintenance...
Страница 47: ...47 Operation...
Страница 83: ...83 Operation Advanced DDC CI...
Страница 87: ...87 Specifications...
Страница 98: ...98 This page left intentionally blank...
Страница 99: ...99 Technical Drawings...
Страница 101: ...101 IND100132 281 Technical Drawings HD 55T22 MVD MA1 TxGx Cable Openings...
Страница 111: ...111 Technical Drawings Accessories...
Страница 116: ...116 This page left intentionally blank...
Страница 117: ...117 Appendixes...
Страница 131: ...131 Appendix IND100077 24 User Notes...
Страница 133: ...133 Revision History Appendix IND100077 161...
Страница 134: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...