background image

SIMATIC VPU200–3104

Hardware Manual

Order Number: PPX:560/65–8102
Manual Assembly Number: 2597773–0006
Second Edition

Содержание SIMATIC VPU200-3104

Страница 1: ...SIMATIC VPU200 3104 Hardware Manual Order Number PPX 560 65 8102 Manual Assembly Number 2597773 0006 Second Edition ...

Страница 2: ...so used for property damage only accidents Copyright 1995 by Siemens Energy Automation Inc All Rights Reserved Printed in USA Reproduction transmission or use of this document or contents is not permitted without express consent of Siemens Energy Automation Inc All rights including rights created by patent grant or registration of a utility model or design are reserved Since Siemens Energy Automat...

Страница 3: ...ber PPX 560 65 8102 Refer to this history in all correspondence and or discussion about this manual Event Date Description Original Issue 07 85 Original Issue 2493916 0001 Errata 1 7 87 Corrects illustration on page 11 2600782 0001 Second Edition 10 95 Second Edition 2493916 0002 ...

Страница 4: ...OF EFFECTIVE PAGES Pages Description Pages Description Cover Copyright Second History Effective Pages Second iii iv Second 1 1 Second 2 1 2 2 Second 3 1 Second 4 1 4 14 Second 5 1 Second Registration Second ...

Страница 5: ...Environmental Considerations 2 2 Chapter 3 VPU200 3104 Specifications Chapter 4 Installation 4 1 VPU200 Voltage Conversion 4 2 4 2 Power Receptacle and Power Cord 4 4 4 3 Operating Positions 4 5 4 4 Controls 4 6 4 5 Communiation Ports 4 7 P C Port 4 7 Auxiliary Port 4 9 5TI Port 4 14 CRU Expansion Port 4 14 Chapter 5 Preventive Maintenance ...

Страница 6: ...le 4 4 4 3 VPU200 Operating Positions 4 5 4 4 VPU200 3104 Controls 4 6 4 5 VPU200 to 560 Cable PPX VPU200 3605 4 7 4 6 VPU200 3104 Modem Cable 4 8 4 7 VPU Printer Port Connector 4 9 4 8 VPU to 733 Cable 300 or 1200 Baud 4 10 4 9 VPU200 to 743 745 Cable 4 11 4 10 VPU200 to 763 765 Cable 4 12 4 11 VPU200 to Model 800 Cable 4 13 4 12 Character Format 4 14 ...

Страница 7: ...ovides you with an overview of the SIMATIC VPU200 VPU200 3014 hardware and gives instructions for connecting the VPU200 3104 to the SIMATIC 560 565 controller as well as to several models of printers which may be used with the VPU200 3104 See Figure 1 1 Figure 1 1 VPU200 3104 Manual Contents ...

Страница 8: ...Description of the VPU200 3104 2 1 SIMATIC VPU200 3104 Hardware Manual Chapter 2 Description of the VPU200 3104 2 1 Introduction 2 2 Handling and Environmental Considerations 2 2 ...

Страница 9: ...and materials must also be used when the VPU200 is to be stored in the baggage or cargo area of a vehicle including the baggage cargo hold of an airplane 3 Because of possible temperature extremes do not transport the VPU200 in the trunk of an automobile For short automobile trips keep the VPU200 in a secure position on one of the seats The VPU200 must have adequate ventilation Be particularly car...

Страница 10: ...ity 10 80 Maximum Wet Bulb of 24 C Shock 2G Any Axis Vibration 5G Any Axis for 30 Minutes 10 60 Hz Input Power 85 to 132 VAC or 195 to 260 VAC Jumper Selected 47 to 63 Hz 90 to 137 Watts 3 AMP Fuse 1 Cycle Dropout Protected Weight 18 KG 40 lbs Dimensions Closed centimeters inches Work Surface centimeters inches Floor centimeters inches Height 43 69 17 2 29 46 11 6 50 29 19 8 Width 23 88 9 4 43 69 ...

Страница 11: ... Manual Chapter 4 Installation 4 1 VPU200 Voltage Conversion 4 2 4 2 Power Receptacle and Power Cord 4 4 4 3 Operating Positions 4 5 4 4 Controls 4 6 4 5 Communication Ports 4 7 P C Port 4 7 Auxiliary Port 4 9 5TI Port 4 14 CRU Expansion Port 4 14 ...

Страница 12: ...use by pulling upward on the black plastic lever 5 When the fuse lever is fully extended and the fuse has been removed use needle nose pliers to remove the small printed circuit board that is mounted vertically next to the fuse holder 6 Rotate the printed circuit board so that the correct voltage will be visible through the clear plastic panel and replace the board 7 Replace the fuse by pressing d...

Страница 13: ...Installation 4 3 SIMATIC VPU200 3104 Hardware Manual Figure 4 1 Top View of VPU Ports Fuse Voltage Selector and Brightness Control ...

Страница 14: ...e same power source as the controller In a noisy environment this is critical for proper performance of the VPU WARNING The wall receptacle for VPU power must accommodate the three pronged male connector The receptacle must have three contacts as shown in Figure 4 2 including one for safety earth ground If a three contact receptacle is not used damage to the terminal and or personal injury can occ...

Страница 15: ...surface or floor position In the work surface position illustrated in Figure 4 3 the support bail on the base of the unit is lowered to hold the VPU in position for use In the floor position the back of the unit and the L shaped brackets mounted on the back form the standing base Figure 4 3 VPU200 Operating Positions ...

Страница 16: ...Installation 4 6 SIMATIC VPU200 3104 Hardware Manual 4 4 Controls Figure 4 4 illustrates the location of the controls Figure 4 4 VPU200 3104 Controls ...

Страница 17: ... Modems must be used when the total cable length is more than 50 feet Figure 4 6 gives the pinouts for the cable PPX VPU200 3605 used with a modem The modem must be plugged into the same power source as the VPU200 and the controller The following settings must be made on a modem used with the VPU200 3104 1 Desired baud rate 2 Full duplex 3 RS 232 C 14 1 25 14 1 25 VPU End 25 Pin D Type Male Connec...

Страница 18: ...8 5 19 6 20 7 8 Modem End 25 Pin D Type Male 560 End 25 Pin D Type Male Connect to Comm 1 13 Max Cable Length 50 Feet Max Cable Length 50 Feet VPU MODEM MODEM 560 13 TX DATA RX DATA RTS CTS DSR SIGNAL GROUND DSR RSD 14 1 25 14 1 25 2 3 4 5 6 20 7 8 15 2 16 3 17 4 18 5 19 6 20 7 8 13 13 TX DATA RX DATA RTS CTS DSR SIGNAL GROUND DSR RSD RTS CTS Figure 4 6 VPU200 3104 Modem Cable ...

Страница 19: ... the VPU200 must have a chassis ground pin 1 isolated from signal ground pin 7 for noise immunity A resistance check should be performed on the printer between pin 1 and pin 7 to insure that the resistance is greater than 20K ohms The printer must also be connected to the same power source as the VPU200 and controller for noise immunity 14 1 25 2 3 4 5 6 20 7 8 13 9 10 11 12 15 16 17 18 19 21 22 2...

Страница 20: ...d for 300 baud The cable shown for 1200 Baud in Figure 4 8 is for use in transporting programs from the VPU to 733 cassette only 14 1 25 2 3 4 5 6 20 7 8 13 P13 VPU END 25 Pin D Type Male Connect to Printer Port A H 10 F 8 9 7 K 6 TO P1 733 END CONNECT TO J1 AT 733 SET 733 FOR 300 BAUD OPERATION for 1200 baud this should be pin C 733 VPU Printer Port P1 MAX CABLE LENGTH 50 FEET DOES NOT REFLECT LE...

Страница 21: ... 9 The VPU and the 743 745 must be set for the same rate either 110 or 300 baud 14 1 25 9 1 VPU End 25 Pin D Type Male Connect to Printer Port 743 745 End 15 Pin D Type Female 15 2 16 3 17 4 18 19 20 7 8 10 11 12 13 14 15 8 13 743 745 VPU Printer Port MAX CABLE LENGTH 50 FEET DOES NOT REFLECT LENGTH OF CABLE Figure 4 9 VPU200 to 743 745 Cable ...

Страница 22: ...e VPU200 must be set at the same baud rate At baud rates above 300 the Record function on the terminal must be activated 14 1 25 9 1 VPU End 25 Pin D Type Male Connect to Printer Port 763 765 End 15 Pin D Type Male Connect to Lower Port 5 2 6 3 4 20 7 14 15 8 13 763 765 VPU Printer Port MAX CABLE LENGTH 50 FEET DOES NOT REFLECT LENGTH TO CABLE 2 3 4 P1 11 Figure 4 10 VPU200 to 763 765 Cable ...

Страница 23: ... 6 and 8 and 9 on the printer processor board Set the printer for 6 lines per inch and 10 characters per inch Any baud rate from 300 to 9600 may be used as long as both the VPU200 and the printer are set at the same rate 14 1 25 14 1 25 VPU End 25 Pin D Type Male Connect to Printer Port 810 End 25 pin D Type Male 2 3 4 5 6 20 7 8 15 2 16 3 17 4 18 5 19 6 20 7 8 13 13 OMNI 800 VPU Printer Port MAX ...

Страница 24: ... printing are pin 3 RX Data pin 7 Signal GND and pin 20 Data terminal ready Data terminal ready is used for printer busy 12 V 12 V 1 0 D D D D D D D 12 V Space Control Signal On Data 0 12 V Mark Control Signal Off Data 1 The transmit line gives data not control Start Bit Parity Bit Odd LSB MSB 7 Bit ASCII Character One Stop Bit for over 110 Baud Two Stop Bits for 110 Baud Figure 4 12 Character For...

Страница 25: ...rive may result in loss of the data on the diskettes Do not insert or remove a diskette from the disk drive unless the VPU is plugged into a power outlet and the On Off switch is On Failure to follow this procedure may result in damage to the diskette Do not leave the VPU in dusty dirty environments for extended periods of time with the cover open Always close the cover and secure both latches whe...

Страница 26: ...tion Clarity Completeness Graphics Examples Overall design Size Index Would you be interested in giving us more detailed comments about our manuals Yes Please send me a questionnaire No Thanks anyway Your Name Title Telephone Number Company Name Company Address Manual Name SIMATIC VPU200 3104 Hardware Manual Edition Second Manual Assembly Number 2597773 0006 Date 10 95 Order Number PPX 560 65 8102...

Страница 27: ... 3 JOHNSON CITY TN FOLD FOLD POSTAGE WILL BE PAID BY ADDRESSEE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES ATTN Technical Communications M S 519 SIEMENS ENERGY AUTOMATION INC 3000 BILL GARLAND RD P O BOX 1255 JOHNSON CITY TN 37605 1255 ...

Страница 28: ... ...

Отзывы: