86/112
WL31/WL31TG
9.0 TELEPHONIC TRX FUNCTIONS
9.1 CALLS CYCLE LOCK
It is possible to lock the calls cycle by inputting the code 12 in the DTMF (defined as “lock code”) of the telephone
device on which a voice call is being received. The lock is made possible on the calls which send a voice message
according to the following method:
10 s
5 s
0,5 s
5 s
BASIC
MESS.
EVENT
MESS.
BEEP
LOCK
WAITING
Structure of a voice message sent
three times:
10 s
5 s
0,5 s
5 s
BASIC
MESS
EVENT
MESS.
BEEP
LOCK
WAITING
10 s
5 s
0,5 s
5 s
BASIC
MESS
EVENT
MESS.
BEEP
LOCK
WAITING
Lock examples
10 s
5 s
0,5 s
5 s
BASIC
MESS.
EVENT
MESS.
BEEP
LOCK
WAITING
DIGIT 12
CYCLE LOCKED
If you enter
the “lock code”, the phone call underway is terminated as well as all the following calls cycle (voice and
GSM). It is also possible to carry out the lock of the calls cycle from the keyboard by inputting a valid code (User
Code or Technician code, if authorised).
CAUTION: TO ENABLE THE OPERATION OF THE CALL LOCK FUNCTION YOU HAVE TO RECORD ALL
THE VOICE MESSAGES
9.2 TELESWITCHING
It is possible to teleswitch the U1 and U2 wire outputs of the control panel, programmed as Service, or activate or
deactivate the system through commands in DTMF from any telephone. If the control panel is enabled (Functions
“Remote Access” and “Deactiv remote” active) the control panel answers to incoming calls at any time, unless it is
under the “event alarm to be sent” condition . The user that wants to carry out a remote control operation must call
the GSM or the PSTN number of the control panel and wait for its response. The response is given after a
programmable number of rings (2, 4 or 8). The response is signalled by the control panel
through a “beep-beep”.
When the control panel has answered, the following steps are:
1.
Enter a valid User’s code (4 to 6 figures) followed by the key “#” within 5 sec. At each figure of the code, a short
confirmation sound is given.
2. Enter within 1 min. the number codes for commutation of the desired outputs or to activate/deactivate the
system:
31 = Activation of alarm system
30 = Deactivation of alarm system
511 = Activation of wire output 1
510 = Deactivation of wire output 1
521 = Activation of wire output 2
520 = Deactivation of wire output 2
For a detailed description of the confirmation signals of the control panel, see the following table. A longer sound
signals an error for:
programmed output different as “Service”
code faulty
command faulty
The wire outputs of the control panel can be configured as toggle (maintaining their state) or impulsive: if the output
is impulsive, upon reception of the command, it will be activated during 2 sec. and then return to rest.
If within 5 sec. from the acknowledgment of the User’s code no code is sent for the remote commutations, the
control panel finishes the call in progress and frees the telephone line.