9 Communication
9.1 AS-Interface
Rapid Link 5 · RAMO5 · RASP5
05/20 MN034004EN
www.eaton.com
197
9.1.9 External Quick stop (for RASP5)
RASP5 provides the option of activating a second Stop function on pins 2 and
4 of the AS-Interface with an external control voltage (+24 V DC). This requi-
res a second ASi ribbon cable and RA-XAZ2-1M connector.
A Quick stop with the second ramp is activated via parameter P3-11.
The ramp time (second ramp) is set using parameter P2-13.
Figure 106:
RA-XAZ2-1M, ASi branch
Figure 107:
Connection example for quick stop
9.1.10 Extension cable
Extension cable RA-XM12-1M can be used to connect the M12 junction
ZB2-100-A21 with Rapid Link 5 modules RAMO5 or RASP5.
This 1 m long connection cable is prefabricated with an M12 socket
(connection to RAMO or RASP) and an M12 plug (M12 junction).
Figure 108:
Extension cable RA-XM12-1M
RA-XAZ2-1M
24 V DC
1
AS-In
2
0 V
3
AS-Interface–
4
24 V
2
4
1
3
+24 V DC
100 mA
External Power
Supply
0 V
3
1
2
4