6 RASP5 speed controller
6.7 Configuration of specific settings
150
Rapid Link 5 · RAMO5 · RASP5
05/20 MN034004EN
www.eaton.com
The following two tables provide an overview of the conditions under which
the sensors cause the drive to stop
Table 28:
Signal detection in Manual mode
Table 29:
Signal detection in Auto mode
Manual mode
P1-13
SEN I1
SEN I2
SEN I3
SEN I4
0
–
–
–
–
1
No function
No function
No function
No function
2
No function
No function
No function
No function
3
No function
No function
No function
No function
4
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
or signal control
No function
No function
5
Stop in FWD operation with
edge control
Stop in FWD operation with
edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
6
No function
No function
No function
No function
7
Stop in FWD operation with
edge control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
8
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
or signal control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
Auto mode
P1-13
SEN I1
SEN I2
SEN I3
SEN I4
0
–
–
–
–
1
No function
No function
No function
No function
2
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
No function
No function
3
Stop in FWD or REV operation
with edge or signal control
No function
No function
No function
4
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
No function
No function
5
Stop in FWD operation with
edge or signal control
Stop in FWD operation with
edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
6
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
7
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
8
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
Содержание Rapid Link 5
Страница 1: ...Manual Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN ...
Страница 4: ...II ...
Страница 38: ...1 Rapid Link 5 system 1 10 Service and warranty 34 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...
Страница 118: ...3 Installation 3 7 Isolation test 114 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...
Страница 196: ...8 Parameter list 8 4 Parameter groups for RASP5 192 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...
Страница 246: ...10 Error Messages 10 2 Error Messages 242 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...