8 Parameter list
8.4 Parameter groups for RASP5
188
Rapid Link 5 · RAMO5 · RASP5
05/20 MN034004EN
www.eaton.com
P5-09
PointerToParameter
Pointer to an internal variable
P5-09 defines the internal variable (or the parameter), whose
value is displayed with P0-59. In addition the value can be
transferred to a fieldbus master vir Process Data Word 3
(PZD3, to be set with P5-05) or 4 (PZD4, to be set with P5-06).
P5-09 is mostly used in conjunction with the Function Block
Editor.
–
0
200
0
P5-10
Disable QuickStop
0: Quick stop via sensors deactivated
1: Quick stop activated via sensors; DQ3 signal active
–
0
1
0
P5-11
AS-i command confi-
guration
Configuration of the 4 AS-Interface outputs DQ0, …, DQ3
0: Clockwise rotation, anticlockwise rotation, FF1 - FF4
(binary coded via Select f-Fix Bit0-1); FWD + REV = Reset
1: Clockwise rotation, FF1 - FF8 (binary coded via Select f-Fix
Bit0-2)
2: Clockwise rotation, selection between 1st and 2nd ramp
time (0= P1-03, P1-04 / 1 = P2-11, P2-13), FF1 - FF4 (binary
coded via Select f-Fix Bit0-1)
–
0
2
0
Parameter
Designation
Description
Unit
Min
Max
DS
Содержание Rapid Link 5
Страница 1: ...Manual Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN ...
Страница 4: ...II ...
Страница 38: ...1 Rapid Link 5 system 1 10 Service and warranty 34 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...
Страница 118: ...3 Installation 3 7 Isolation test 114 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...
Страница 196: ...8 Parameter list 8 4 Parameter groups for RASP5 192 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...
Страница 246: ...10 Error Messages 10 2 Error Messages 242 Rapid Link 5 RAMO5 RASP5 05 20 MN034004EN www eaton com ...