CHAPTER 5 - PXG200E THEORY OF OPERATION
11
EATON
PXG200E User Manual • IM02603001E
Rev 5, 11-May-2012 • Firmware Version 5.03:3835
Chapter 5
PXG200E Theory of Operation
This section explains how the PXG200E works and provides information that
will help you configure, install and integrate the product successfully.
The PXG200E allows you to access and view data from multiple devices on a
mix of downstream industrial networks via multiple clients on an Ethernet
Local Area Network (LAN). Supported industrial network protocols include
INCOM and Modbus RTU. The PXG200E is capable of supporting INCOM
and Modbus RTU devices. This provides the ability to communicate with
Eaton and third party equipment using one PXG200E. A typical Power Xpert
system, incorporating Power Xpert Gateways, is shown in
.
Figure 2
Powe
r
Xpe
r
t
S
oftwa
r
e
(
S
MTP)
Web B
r
owse
r
(WAN)
Data
Expo
r
t
(
c
sv)
Data
T
r
ending
Web B
r
owse
r
(LAN)
HTTP
Inte
r
net
Wavefo
r
m
C
aptu
r
e and A
c
quisition
3
r
d Pa
r
ty HMI
S
oftwa
r
e
Modbus T
C
P/IP
NTP
Powe
r
Xpe
r
t
Mete
r
4000/6000/8000
BA
C
net/W
S
+
Moto
r
C
ont
r
ols
Powe
r
Xpe
r
t
G
ateway 600E
BA
C
net/W
S
+
Powe
r
Dist
r
ibution
Powe
r
Xpe
r
t
Ethe
r
net
S
wit
c
h
Powe
r
Xpe
r
t
G
ateway 800E
IQ Analyze
r
Mete
r
w/PONI
C
a
r
d
IQ 250/250
Mete
r
s
IQ 130/140/150
Mete
r
s
Advantage
C
ent
r
al
Monito
r
ing
Unit
w/WPONI
Multi-
Po
r
t
Devi
c
e
S
e
r
ve
r
Powe
r
Xpe
r
t
G
ateway 400E
AT
S
S
T
S
PDU
G
EN &
C
TRL
C
RA
C
Cr
iti
c
al Powe
r
Dist
r
ibution &
C
ooling
Eaton
PDU
EOLR
F
r
eedom
M
CC
S
VX9000
MVX9000
D
r
ive
Insul
G
a
r
d
Relays
IQ DP-4000
Mete
r
w/PONI
C
a
r
d
IQ 220/230
Mete
r
s
DT-1150
T
r
ip Unit
B
r
eake
r
Inte
r
fa
c
e
Module w/PONI
C
a
r
d
OPTIM T
r
ip Unit
MP-3000/4000
FP-4000/5000
Moto
r
P
r
ote
c
tion
Relays
Powe
r
S
entinel Mete
r
Ene
r
gy
S
entinel Mete
r
EOLR
EOLR
EOLRT
EOLRT
LV
S
wit
c
hgea
r
MV
S
wit
c
hgea
r
MV
S
ta
r
te
r
Eaton
UP
S
3
r
d Pa
r
ty Moto
r
Relays
3
r
d Pa
r
ty
P
r
ote
c
tive
Relays
3
r
d Pa
r
ty
PQ Mete
r
s
Ethe
r
net Netwo
r
k
Q
C
Po
r
t Netwo
r
k
IN
C
OM Netwo
r
k
R
S
-485 Netwo
r
k
EOLR
EOLTR
End of line te
r
mination
r
esisto
r
End of line
r
esisto
r
18
17
15
2
4
14
13
12
6
7
8
9
10
11
5
3
1
Netwo
r
k Time
S
e
r
ve
r
Powe
r
Xpe
r
t
Mete
r
2000
Powe
r
Xpe
r
t
Ethe
r
net
S
wit
c
h
Powe
r
Xpe
r
t
G
ateway 200E
IQ 35M
IQ ME
S
II
20
19
BA
C
net/IP
C
441
Ove
r
load Relay
o
16
Digtal Input
Module KYZ
3
PXG200E_209
1 Power Xpert Software
2 Power Xpert Meter 4000/6000/8000
3 Power Xpert 6-Port Ethernet Switch
4 Power Xpert Gateway
5 Power Xpert Gateway
6 IQ Analyzer
7 Digitrip DT1150
8 Breaker Interface Module
9 OPTIM Trip Unit
10 MP-3000/MP-4000/MD-
3000/DT-3000/FP-4000/FP-5000
11 Energy/Power Sentinel
12 IQ 130/140/150 Meters
13 IQ 250/260 Meters
14 InsulGard™ Relay
15 SVX9000/MVX9000 Drive
16 Digital Input Module KYZ
17 Eaton PDU w/PXGX PDP Card
18 Eaton UPS w/PXGX UPS Card
19 IQ 35M
20 IQ MESII
Legend:
RETURN