7.7.6.3 Group Stop Command
There’re two different ways to stop axis group motion:
Programming stop
Use DMC_GroupStop in the programming to decelerate the moving axis group to a stop. Then the group
state switches to GroupStopping, which no motion instruction can be executed under this status.
The velocity for a deceleration stop must be set to the lrDeceleration pin.
Error stop
As soon as an error occurs in group motion, the axis group stops operating.
For example, Hardware Limit is reached while the axis group is moving. The velocity drops to zero as a
result of the output CommandAborted.
Hardware Limit
Velocity
3000
CommandAborte