C h a p t e r 7 M o t i o n C o n t r o l B a s i c S e t t i n g s & O p e r a t i o n
7 - 1 7
7_
Axis status and communication status
Name
Function
Status
Axis status
Communication
Communication status
Axis power: Set power ON/ OFF.
Error reset: Clear error messages of servo axis.
Homing: Make the axis back to the start position.
Inch
Name
Function
Distance
Moving distance
Velocity
Moving velocity
Acceleration
Acceleration rate
Deceleration
Deceleration rate
Jerk
Command value of jerk
Read&Write: Read-write parameters of upper axes. If need be, you can read and modify Object
Dictionary by inputting as follows.
-
Read and write the parameter 0x6098 in object dictionary
1 = fixed number
6098 =the parameter to be read and written
00 = sub of the parameter
1. Convert 0x1609800 to demical number as 23,107,584
2. Change 23,107,584 to -23,107,584
3. Enter -23,107,584 in the “Parameter” field to read the parameter “0x6098”.
Содержание AX-3 Series
Страница 17: ...AX 3 Series Operation Manual 1 10 _1 MEMO...
Страница 54: ...AX 3 Series Operation Manual 3 22 _3 MEMO...
Страница 98: ...AX 3 Series Operation Manual 4 44 _4 MEMO...
Страница 118: ...AX 3 Series Operation Manual 6 8 _6 MEMO...
Страница 148: ...AX 3 Series Operation Manual 7 30 _7 Scan PLC controller Add the newly scanned PLC controller and click OK...
Страница 241: ...Chapter 7 Motion Control Basic Settings Operation 7 123 7_ Click to enter Axis 0 tab on PoAxis Configuration page...
Страница 292: ...AX 3 Series Operation Manual 7 174 _7 Jerk Done MC_MoveSuperImposed_Done Busy CommandAborted Error ErrorID...
Страница 310: ...AX 3 Series Operation Manual 8 18 8_ MEMO...
Страница 355: ...Appendix A Troubleshooting A 5 _A...