C h a p t e r 7 M o t i o n C o n t r o l B a s i c S e t t i n g s & O p e r a t i o n
7 - 8 7
7_
7.7.4 Torque control
Torque control can be categorized into Cyclic Synchronous Torque mode (CST) and Profile Torque mode (PT).
Profile Torque mode (PT)
-
Use DMC_TorqueControl to generate assigned torque output continuously through single axes.
-
Notification
•
When using DMC_TorqueControl, switch the control mode to cyclic synchronous torque mode.
•
When using MC_TorqueControl, the control mode switches to torque mode and cannot use function
blocks regarding shifts or velocity. Use MC_TorqueControl Enable instead of MC_Stop to stop motors.
•
Do not set Torque to 0, when setting is 0, MC_TorqueControl is reported as error.
•
Use the velocity of DMC_TorqueControl to set the maximum velocity limit for servo motors which avoids
high speed rotation as motor load declines in torque mode.
•
Adopt TorqueRamp to achieve the target torque value.
•
When Torque is bigger than 0 (Torque > 0), the motor operates in positive direction.
•
When Torque is smaller than 0 (Torque < 0), the motor operates in negative direction.
Содержание AX-3 Series
Страница 17: ...AX 3 Series Operation Manual 1 10 _1 MEMO...
Страница 54: ...AX 3 Series Operation Manual 3 22 _3 MEMO...
Страница 98: ...AX 3 Series Operation Manual 4 44 _4 MEMO...
Страница 118: ...AX 3 Series Operation Manual 6 8 _6 MEMO...
Страница 148: ...AX 3 Series Operation Manual 7 30 _7 Scan PLC controller Add the newly scanned PLC controller and click OK...
Страница 241: ...Chapter 7 Motion Control Basic Settings Operation 7 123 7_ Click to enter Axis 0 tab on PoAxis Configuration page...
Страница 292: ...AX 3 Series Operation Manual 7 174 _7 Jerk Done MC_MoveSuperImposed_Done Busy CommandAborted Error ErrorID...
Страница 310: ...AX 3 Series Operation Manual 8 18 8_ MEMO...
Страница 355: ...Appendix A Troubleshooting A 5 _A...