C h a p t e r 7 M o t i o n C o n t r o l B a s i c S e t t i n g s & O p e r a t i o n
7 - 2 9
7_
The rotation range must be defined after finishing rotary axis settings. Please setup “Modulo value” IN
“Modulo settings”.
Scaling/ Mapping page
Set the pulse value for “Command pulse per motor rotation”. Set the movement distance within one full
motor retation for “Pitch”.
To configure the communication cycle time of Ethernet, click “EtherCAT_Master_SoftMotion”, then set the
value of “Cycle time” as 2000 and “Sync offset” as 50.