C h a p t e r 4 B a s ic O p e r a t i o n
4 - 11
_4
4.2.1.6
PLC Settings
You can make the basic settings for the configuration of the PLC here, for example the handling of inputs and outputs
and the bus cycle task.
➀
Application for I/O handling
Item
Description
Application for I/O handling
Application that is for the I/O handling.
➁
PLC Settings
Item
Description
Update IO while in stop
:
DIADesigner-AX
does not refresh the values of the input and output channels
when the PLC is in the stop state.
:
DIADesigner-AX
refreshes the values of the input and output channels even if
the PLC is in the stop state. If the watchdog detects a malfunction, the outputs
are set to the predefined default values.
Behavior of the outputs in
stop
Handling of the output channels when the controller enters the stop state:
•
Keep current values:
The current values are retained.
•
Set all outputs to default:
The default values resulting from the I/O
mapping are assigned.
•
Execute program:
You can control the handling of the output values via a
program contained in the project, which DIADesigner-AX executes at
“STOP”. Enter the name of the program in the field on the right.
Always update variables
Global setting that defines whether or not
DIADesigner-AX
updates the I/O
variables in the bus cycle task. This setting is effective for I/O variables of the
slaves and modules only if ‘disabled’ is defined in their update settings.
•
Disabled (update only if used in a task):
DIADesigner-AX updates the I/O
variables only if they are used in a task.
•
Enabled 1 (use bus cycle task if not used in another task
): DIADesigner-
AX updates the I/O variables in the bus cycle task if they are not used in any
other task.
•
Enabled 2 (always in bus cycle task
): DIADesigner-AX updates all
variables in each cycle of the bus cycle task, regardless of whether they are
used and whether they are mapped to an input or output channel.
Содержание AX-3 Series
Страница 17: ...AX 3 Series Operation Manual 1 10 _1 MEMO...
Страница 54: ...AX 3 Series Operation Manual 3 22 _3 MEMO...
Страница 98: ...AX 3 Series Operation Manual 4 44 _4 MEMO...
Страница 118: ...AX 3 Series Operation Manual 6 8 _6 MEMO...
Страница 148: ...AX 3 Series Operation Manual 7 30 _7 Scan PLC controller Add the newly scanned PLC controller and click OK...
Страница 241: ...Chapter 7 Motion Control Basic Settings Operation 7 123 7_ Click to enter Axis 0 tab on PoAxis Configuration page...
Страница 292: ...AX 3 Series Operation Manual 7 174 _7 Jerk Done MC_MoveSuperImposed_Done Busy CommandAborted Error ErrorID...
Страница 310: ...AX 3 Series Operation Manual 8 18 8_ MEMO...
Страница 355: ...Appendix A Troubleshooting A 5 _A...