C h a p t e r 4 B a s ic O p e r a t i o n
4 - 3 1
_4
4.3.2.2
Address Assignments
In AX308E, there are three ranges in the memory area, including I (input memory range), Q (output memory range) and M
(flag memory range). You can use specific character strings to express memory position and size. For the M flag memory
range in AX-3 Series PLC, you cannot manually use the bit operation when in online mode.
Syntax: %<Memory Area Prefix><Size Prefix><Memory Position>
Memory Area
Description
Range
I
Input Memory Range
8 KB
Q
Output Memory Range
8 KB
M
Flag Memory Range
512 KB
Size Prefix
Data Type
Data Width
X
--
1 bit
B
Byte
8 bit
W
Word
16 bit
D
DWord
32 bit
L
LWord
64 bit
•
Memory Area
The numbering that you use for addressing the memory position depends on the target system. Before specifying the
address value in the memory area, you need to know the mapping corresponding relationship of devices to prevent the
overlapping memory ranges. See the table below for reference.
Memory Area
X0.63~X0.56
X0.55~X0.48 X0.47~X0.40 X0.39~X0.32 X0.31~X0.17 X0.23~X0.16 X0.15~X0.8
X0.7~X0.0
X7.7~X7.0
X6.7~X6.0
X5.7~X5.0
X4.7~X4.0
X3.7~X3.0
X2.7~X2.0
X1.7~X1.0
X0.7~X0.0
B7
B6
B5
B4
B3
B2
B1
B0
W3
W2
W1
W0
D1
D0
L0
Содержание AX-3 Series
Страница 17: ...AX 3 Series Operation Manual 1 10 _1 MEMO...
Страница 54: ...AX 3 Series Operation Manual 3 22 _3 MEMO...
Страница 98: ...AX 3 Series Operation Manual 4 44 _4 MEMO...
Страница 118: ...AX 3 Series Operation Manual 6 8 _6 MEMO...
Страница 148: ...AX 3 Series Operation Manual 7 30 _7 Scan PLC controller Add the newly scanned PLC controller and click OK...
Страница 241: ...Chapter 7 Motion Control Basic Settings Operation 7 123 7_ Click to enter Axis 0 tab on PoAxis Configuration page...
Страница 292: ...AX 3 Series Operation Manual 7 174 _7 Jerk Done MC_MoveSuperImposed_Done Busy CommandAborted Error ErrorID...
Страница 310: ...AX 3 Series Operation Manual 8 18 8_ MEMO...
Страница 355: ...Appendix A Troubleshooting A 5 _A...