A X - 3 S e r i e s O p e r a t i o n M a n u a l
7 - 1 4 2
_7
If a quick stop is performed by MC_Stop during execution of MC_MoveAbsolute, MC_MoveAbsolute would be
aborted and be in Stopping state.
//MC_MoveAbsolute & MC_Stop
MC_MoveAbsolute_0(
Axis:= SM_Drive_Virtual,
Execute:= MC_MoveAbsolute0_Execute,
Position:= 10000.0,
Velocity:= 500.0,
Acceleration:= 500.0,
Deceleration:= 500.0,
Jerk:= ,
Direction:= MC_DIRECTION.positive,
Done=> ,
Busy=> ,
CommandAborted=> ,
Error=> ,
ErrorID=>);
MC_Stop_0(
Axis:= SM_Drive_Virtual,
Execute:= StopOn,
Deceleration:= 5000.0,
Jerk:= ,
Done=> ,
Busy=> ,
Error=> ,
ErrorID=>);
7.8.2.5 Home Positioning
Use homing instruction in the the following example to let you understand how to perform the homing operation.
Currently, a total of 36 homing modes (0~35) are supported and the OD is 6098(Homing method)
/6099sub1(Speed during search for switch) /6099sub2(Speed during search for zero). For more details, please
refer to Delta High Resolution AC Servo Drive ASDA-A2 Series User Manual.
For the following example, specify the parameters of OD as mentioned above after adding A2-E sevo in EtherCAT
Slave.
Choose mode 33 for Homing Method (Perform homing operation once meet the first Z pulse.)
Speed during search for switch =1000 (Unit: 0.1rpm) (Search for limit switch at the speed of 100rmp.)
Speed during search for zero =100 (Unit: 0.1rpm) (Search for zero at the speed of 10rmp.)
After settings are completed, the homing method for executing MC_Home with LD/ ST language would be
corresponding to the one specified as above.
Содержание AX-3 Series
Страница 17: ...AX 3 Series Operation Manual 1 10 _1 MEMO...
Страница 54: ...AX 3 Series Operation Manual 3 22 _3 MEMO...
Страница 98: ...AX 3 Series Operation Manual 4 44 _4 MEMO...
Страница 118: ...AX 3 Series Operation Manual 6 8 _6 MEMO...
Страница 148: ...AX 3 Series Operation Manual 7 30 _7 Scan PLC controller Add the newly scanned PLC controller and click OK...
Страница 241: ...Chapter 7 Motion Control Basic Settings Operation 7 123 7_ Click to enter Axis 0 tab on PoAxis Configuration page...
Страница 292: ...AX 3 Series Operation Manual 7 174 _7 Jerk Done MC_MoveSuperImposed_Done Busy CommandAborted Error ErrorID...
Страница 310: ...AX 3 Series Operation Manual 8 18 8_ MEMO...
Страница 355: ...Appendix A Troubleshooting A 5 _A...