C h a p t e r 7 M o t i o n C o n t r o l B a s i c S e t t i n g s & O p e r a t i o n
7 - 4 3
7_
7.5.2 Variables for Axis Group
After creating axis groups in project tree with DIADesigner-AX, the corresponding axis variables will be generated
automatically, which are set out in the following table.
Name
Data Type
Setting Value
(Default Value)
Function
GroupState
DMC_
GROUP_
STATE
GroupDisabled /
GroupStandby /
GroupMoving /
GroupHoming /
GroupStopping /
GroupErrorstop
(GroupDisabled)
Commands for axis group status.
bError
BOOL
TRUE / FALSE
(FALSE)
TRUE when an error occurs in the
axis group
dwErrorId
DMC_
ERROR
DMC_ERROR
(DMC_GM_NO_
ERROR)
Detailed error description
lrVelocity
LREAL
0 ~ 1.798E+308
(0)
Current velocity of axis group
lrAcceleration
LREAL
Positive number, negative
number or zero
(0)
Current acceleration of axis group
lrJerk
LREAL
Positive number, negative
number or zero
(0)
Current jerk of axis group
bAccelerating
BOOL
TRUE / FALSE
(FALSE)
TRUE when accelerating
bDecelerating
BOOL
TRUE / FALSE
(FALSE)
TRUE when decelerating
bConstantVelocity
BOOL
TRUE / FALSE
(FALSE)
TRUE when moving at a constant
velocity (including zero velocity)
bInPosition
BOOL
TRUE / FALSE
(FALSE)
TRUE when positioning is done.
Axis_X_Name
String
Display the Axis_X name for current
axis group
Axis_Y_Name
String
Display the Axis_Y name for current
axis group
Axis_Z_Name
String
Display the Axis_Z name for current
axis group
Axis_A_Name
String
Display the Axis_A name for current
axis group
Axis_B_Name
String
Display the Axis_B name for current
axis group
Axis_C_Name
String
Display the Axis_C name for current
axis group
RampType
DMC_GROUP_
RAMP_TYPE
Trapezoid / S Curve
(S Curve)
Ramp type of current S-curve
lrMaxVelocityLimit
LREAL
Positive number or zero
The max velocity of axis group
Содержание AX-3 Series
Страница 17: ...AX 3 Series Operation Manual 1 10 _1 MEMO...
Страница 54: ...AX 3 Series Operation Manual 3 22 _3 MEMO...
Страница 98: ...AX 3 Series Operation Manual 4 44 _4 MEMO...
Страница 118: ...AX 3 Series Operation Manual 6 8 _6 MEMO...
Страница 148: ...AX 3 Series Operation Manual 7 30 _7 Scan PLC controller Add the newly scanned PLC controller and click OK...
Страница 241: ...Chapter 7 Motion Control Basic Settings Operation 7 123 7_ Click to enter Axis 0 tab on PoAxis Configuration page...
Страница 292: ...AX 3 Series Operation Manual 7 174 _7 Jerk Done MC_MoveSuperImposed_Done Busy CommandAborted Error ErrorID...
Страница 310: ...AX 3 Series Operation Manual 8 18 8_ MEMO...
Страница 355: ...Appendix A Troubleshooting A 5 _A...