Chapter 7 Servo Parameters
|
ASDA-A&A+ Series
7-88
Revision April 2009
P4 - 19
TIGB
IGBT NTC Calibration
Communication Addr.: 0413H
Default: Factory setting
Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 1~7
Settings:
Manual Adjustment Operation:
Set parameter P2-08 to 22 and then change this parameter. This is an auxiliary adjusting
function, although this parameter allows the users can execute manual adjustment, we still do
not recommend users to change the default setting manually.
Auto Adjustment Operation:
Set parameter P2-08 to 20 first and then set parameter P4-10 to 6. When executing this auto
adjustment, please ensure to cool the servo drive to 25
o
C.
NOTE
1) When P2-08 is set to 10, users cannot reset this parameter.
P4 - 20
DOF1
Analog Monitor Output Drift Adjustment (CH1)
Communication Addr.: 0414H
Default: Factory setting
Related Section:
Applicable Control Mode: ALL
Section 6.4.4
Unit: mV
Range: -800~800
Settings:
When P2-08 is set to 10, users cannot reset this parameter.
P4 - 21
DOF2
Analog Monitor Output Drift Adjustment (CH2)
Communication Addr.: 0415H
Default: Factory setting
Related Section: N/A
Applicable Control Mode: ALL
Section 6.4.4
Unit: mV
Range: -800~800
Settings:
When P2-08 is set to 10, users cannot reset this parameter.