Chapter 7 Servo Parameters
|
ASDA-A&A+ Series
7-2
Revision April 2009
7.2 Parameters
Summary
7.2.1 Parameters List by Group
Group 0: P0-xx
Monitor Parameters
Control Mode
Parameter
Name
Function
Default
Unit
Pt Pr S
T
P0-00
★
VER Firmware
Version
Factory
setting
N/A
{
{ { {
P0-01
★
ALE
Drive Fault Code
N/A
N/A
{
{ { {
P0-02 STS
Drive
Status
00 N/A
{
{ { {
P0-03
MON
Analog Monitor Output
01
N/A
{
{ { {
P0-04
CM1
Status Monitor 1
0
N/A
{
{ { {
P0-05
CM2
Status Monitor 2
0
N/A
{
{ { {
P0-06
CM3
Status Monitor 3
0
N/A
{
{ { {
P0-07
CM4
Status Monitor 4
0
N/A
{
{ { {
P0-08
CM5
Status Monitor 5
0
N/A
{
{ { {
P0-09
MAP0
Block Data Read / Write Register 0
407H
N/A
{
{ { {
P0-10
MAP1
Block Data Read / Write Register 1
10FH
N/A
{
{ { {
P0-11
MAP2
Block Data Read / Write Register 2
110H
N/A
{
{ { {
P0-12
MAP3
Block Data Read / Write Register 3
224H
N/A
{
{ { {
P0-13
MAP4
Block Data Read / Write Register 4
111H
N/A
{
{ { {
P0-14
MAP5
Block Data Read / Write Register 5
112H
N/A
{
{ { {
P0-15
MAP6
Block Data Read / Write Register 6
225H
N/A
{
{ { {
P0-16
MAP7
Block Data Read / Write Register 7
109H
N/A
{
{ { {
P0-17
SVSTS Servo Output Status Display
N/A
N/A
{
{ { {
Explanation of symbols (marked after parameter)
(
★
) Read-only
register.
(
▲
)
Parameter cannot be set when Servo On (when the servo drive is enabled).
(
●
)
Parameter is effective only after the servo drive is restarted (after switching power off and on).
(
■
)
Parameter setting values are not retained when power is off.