Chapter 7 Servo Parameters
|
ASDA-A&A+ Series
Revision April 2009
7-91
Sign
Setting
Value
Digital Input Function Description
POS0 11
POS1 12
POS2 13
Position command selection 0 ~ 2
When the Pr mode is selected, the 8 stored positions are programmed via a
combination of the POS 0, POS 1, and POS 2 commands.
Command No.
POS2
POS1
POS0
CTRG
Parameter
P1-15
P1
OFF OFF OFF
P1-16
P1-17
P2 OFF
OFF
ON
P1-18
P1-19
P3 OFF
ON
OFF
P1-20
P1-21
P4 OFF
ON
ON
P1-22
P1-23
P5 ON
OFF
OFF
P1-24
P1-25
P6 ON
OFF
ON
P1-26
P1-27
P7 ON
ON
OFF
P1-28
P1-29
P8
ON ON ON
P1-30
SPD0 14
SPD1 15
Speed command selection 0 ~ 1
DI signal of CN1
Command
No.
SPD1 SPD0
Command Source
Content
Range
S
External
analog
command
Voltage between
V-REF and GND
+/- 10 V
S1 OFF
OFF
Mode
Sz None
Speed command
is 0
0
S2
OFF
ON
P1-09
+/- 5000 r/min
S3
ON
OFF
P1-10
+/- 5000 r/min
S4 ON
ON
Internal parameter
P1-11
+/- 5000 r/min
TCM0 16
TCM1 17
Torque command selection 0 ~ 1
DI signal of CN1
Command
No.
TCM1 TCM0
Command Source
Content
Range
T
Analog
command
Voltage between
V-REF and GND
+/- 10 V
T1 OFF
OFF
Mode Tz None
Torque command
is 0
0
T2
OFF
ON
P1-12
+/- 300 %
T3
ON
OFF
P1-13
+/- 300 %
T4 ON
ON
Internal parameter
P1-14
+/- 300 %
S-P
18
Speed / Position mode switching (OFF: Speed, ON: Position) (see section 6.5)