Chapter 7 Servo Parameters
|
ASDA-A&A+ Series
7-84
Revision April 2009
P4 - 11
SOF1
Analog Speed Input Drift Adjustment 1
Communication Addr.: 040BH
Default: Factory setting
Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0~32767
Settings:
Manual Adjustment Operation:
Set parameter P2-08 to 22 and then change this parameter. This is an auxiliary adjusting
function, although this parameter allows the users can execute manual adjustment, we still do
not recommend users to change the default setting manually.
Auto Adjustment Operation:
Set parameter P2-08 to 20 first and then set parameter P4-10 to 1. When executing this auto
adjustment, please short the internal circuit of the analog input voltage first or connecting to a 0V
output of the external controller in advance and make sure that the status of the servo drive is
“Servo Off”.
NOTE
1) When P2-08 is set to 10, users cannot reset this parameter.
P4 - 12
SOF2
Analog Speed Input Drift Adjustment 2
Communication Addr.: 040CH
Default: Factory setting
Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0~32767
Settings:
Please see P4-11 for explanation.
NOTE
1) When P2-08 is set to 10, users cannot reset this parameter.