Chapter 6 Control Modes of Operation
|
ASDA-A&A+ Series
Revision April 2009
6-43
ASDA-A+ Series
Allowable frequency when the servo motor run without load (times/min)
and uses built-in regenerative resistor
3.0kW
3.5KW
4.5kW
Motor Capacity
Servo Motor
30
35
45
ECMA Series
11
11
8
When the servo motor runs with load, the allowable frequency will change according to the changes of
the load inertia and rotation speed. Use the following equation to calculate the allowable frequency.
Allowable fr equency =
Allowable frequency when serv o motor run without load
m + 1
x
Rated s peed
Operating speed
times
mi n.
2
m = load/motor inertia ratio
The users can select the adequate external regenerative resistors according to the allowable frequency
by referring to the table below:
ASDA-A Series
Allowable frequency when the servo motor run without load (times/min)
and uses external regenerative resistor
ASMT
L
100W
200W
400W
750W
1.0kW 1.5kW 2.0kW 3.0kW
Motor Capacity
Recommended
Regenerative Resistor
Specifications
01
02
04
07
10
15
20
30
400W 40
Ω
-
-
7137
2247
933
674
-
-
1kW 20
Ω
- - - -
2333
1685
1291
523
Allowable frequency when the servo motor run without load (times/min)
and uses external regenerative resistor
ASMT
M
1.0kW
1.5kW
2.0kW
3.0kW
Motor Capacity
Recommended
Regenerative Resistor
Specifications
10
15
20
30
400W 40
Ω
913
621
-
-
1kW 20
Ω
2282
1552
863
315
ASDA-A+ Series
Allowable frequency when the servo motor run without load (times/min)
and uses external regenerative resistor
ECMA Series
3.0kW
3.5KW
4.5kW
Motor Capacity
Recommended
Regenerative Resistor
Specifications
30
35
45
3kW 10
Ω
331
331
234
Call 1(800)985-6929 for Sales