Steps
1. Disconnect all the power cables from the power supply unit (PSU) to the system board, hard drive backplane, hard drives, and optical
drives.
2. Remove the screw securing the PSU to the chassis and slide the PSU out of the PSU cage.
Figure 73. Removing a cabled AC PSU
1. screw
2. PSU cage
3. non-redundant PSU
4. standoff on the chassis
5. P2 power cable connector
6. P1 signal cable connector
7. P1 power cable connector
8. P4/backplane connector
Next steps
1. Install a cabled PSU.
2. Follow the procedure listed in the After working inside your system section.
Related tasks
Installing a cabled power supply unit
on page 118
Installing a cabled power supply unit
Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and
118
Installing and removing system components