Option
Description
OS Watchdog
Timer
If your system stops responding, this watchdog timer aids in the recovery of your operating system. When this
option is set to
Enabled
, the operating system initializes the timer. When this option is set to
Disabled
(the
default), the timer does not have any effect on the system.
Memory Mapped
I/O above 4 GB
Enables or disables the support for PCIe devices that need large amounts of memory. This option is set to
Enabled
by default.
Slot Disablement
Enables or disables the available PCIe slots on your system. The slot disablement feature controls the
configuration of PCIe cards installed in the specified slot. Slots must be disabled only when the installed peripheral
card prevents booting into the operating system or causes delays in system startup. If the slot is disabled, both
the Option ROM and UEFI drivers are disabled.
Serial Communication details
About this task
The
Serial Communication
screen details are explained as follows:
Option
Description
Serial
Communication
Selects serial communication devices (Serial Device 1 and Serial Device 2) in BIOS. BIOS console redirection can
also be enabled and the port address can be specified. This option is set to
Auto
by default.
Serial Port
Address
Enables you to set the port address for serial devices. This option is set to
Serial Device 1=COM2, Serial
Device 2=COM1
by default.
NOTE:
You can use only Serial Device 2 for the Serial Over LAN (SOL) feature. To use console
redirection by SOL, configure the same port address for console redirection and the serial device.
NOTE:
Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The
serial MUX setting can independently be changed in iDRAC. Loading the BIOS default settings
from within the BIOS setup utility may not always revert the serial MUX setting to the default
setting of Serial Device 1.
External Serial
Connector
Enables you to associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access
Device by using this option.
NOTE:
Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by
SOL, configure the same port address for console redirection and the serial device.
NOTE:
Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The
serial MUX setting can independently be changed in iDRAC. Loading the BIOS default settings
from within the BIOS setup utility may not always revert this setting to the default setting of
Serial Device 1.
Failsafe Baud Rate
Specifies the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate
automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. This
option is set to
115200
by default.
Remote Terminal
Type
Sets the remote console terminal type. This option is set to
VT 100/VT 220
by default.
Redirection After
Boot
Enables or disables the BIOS console redirection when the operating system is loaded. This option is set to
Enabled
by default.
System Profile Settings details
About this task
The
System Profile Settings
screen details are explained as follows:
Pre-operating system management applications