33
MYDENS
COSMOGAS
5 - INSTALLATION
5.17.5 - “60/100PP Vertical coaxial”
system (polypropylene) (Type C13;
C33)
The appliance is supplied as per standard without fittings to
connect the flue exhaust/air intake.
To connect the appliance to a 60/100 vertical coaxial
system, the relevant kit must be requested and must be
installed as in Figure 31.
a
WARNING!!! Scrupulously follow the installation
phases of the coaxial duct as illustrated in Figure 33.
a
WARNING!!! The exhaust and intake ducts
must be appropriately sustained via rigid brackets
positioned no more than 1 metre from each other.
The brackets must be fixed to rigid walls that can
support the weight of the pipe itself.
a
WARNING!!! Once these operations have been
performed, check that the exhaust/intake terminal is
exposed to the outdoors with the tolerances given in
Figure 36.
l
Take particular care with the installation of ducts
in the part that passes through the wall to the outside;
the normal maintenance operations must always be
possible, therefore, install the pipes in a sheath so that
they can be slid out.
l
The horizontal tracts must always have an inclination
of at least 2% towards the condensate drain device.
The flue exhaust/air intake system can be extended up to
a maximum distance as indicated in section 9. Every 90°
bend has a loss equivalent to the value in section 9. Every
45° bend has a loss equivalent to the value in section 9.
B
D
A
C
020002.01.012
Figure 31
Figure 32
Figure 33
Содержание Adveco MYDENS 15B
Страница 10: ...10 MYDENS COSMOGAS 4 OPERATION Figure 3 MYDENS 24P MYDENS 34P Figure 4 MYDENS 15B MYDENS 24B MYDENS 34B...
Страница 88: ...88 MYDENS COSMOGAS 8 MAINTENANCE 8 26 Wiring diagram Figure 77...
Страница 96: ...COSMOGAS s r l Via L da Vinci 16 47014 Meldola FC Italia info cosmogas com www cosmogas com...