7-29
Firepower 7000 and 8000 Series Installation Guide
Chapter 7 Hardware Specifications
Firepower 8000 Series Devices
Firepower 8000 Series Physical and Environmental Parameters
The following table describes the physical attributes and environmental parameters for AMP8x50 and
81xx Family devices.
Table 7-42
AMP8x50 and 81xx Family Physical and Environmental Parameters
Parameter
Description
Form factor
1U
Dimensions
(D x W x H)
28.7 in. x 17.2 in. x 1.73 in. (72.8 cm x 43.3 cm x 4.4 cm)
Weight
maximum installed
43.5 lbs (19.8 kg)
Copper 1000BASE-T
configurable bypass
NetMod
Quad-port Gigabit copper Ethernet configurable bypass interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Fiber 10GBASE
configurable bypass
MMSR or SMLR NetMod
Dual-port fiber configurable bypass interfaces with LC connectors
Cable and distance:
LR is single-mode at 5000 m (available)
SR is multimode fiber (850 nm) at 550 m (standard)
Fiber 1000BASE-SX
configurable bypass
NetMod
Quad-port fiber configurable bypass interfaces 1000BASE-SX with LC connectors
Cable and distance: SX is multimode fiber (850 nm) at 550 m (standard)
Copper 1000BASE-T
non-bypass NetMod
Quad-port Gigabit copper Ethernet non-bypass interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Fiber 10GBASE
non-bypass
MMSR or SMLR NetMod
Quad-port fiber non-bypass interfaces with LC connectors
Cable and distance:
LR is single-mode at 5000 m (available)
SR is multimode fiber (850 nm) at 550 m (standard)
Fiber 1000BASE-SX
non-bypass NetMod
Quad-port fiber non-bypass interfaces 1000BASE-SX with LC connectors
Cable and distance: SX is multimode fiber (850 nm) at 550 m (standard)
Power supply
Dual 650 W redundant power supplies designed for AC or DC.
AC Voltage: 100 VAC to 240 VAC nominal (85 VAC to 264 VAC maximum)
AC Current: 5.2A maximum over the full range, per supply
2.6A maximum for 187 VAC to 264 VAC, per supply
AC Frequency range: 47 Hz to 63 Hz
DC Voltage: -48 VDC nominal referenced to RTN
-40 VDC to -72 VDC maximum
DC Current: 11A maximum, per supply
Operating temperature
50°F to 95°F (10°C to 35°C)
Non-operating temperature -29°F to 158°F (-20°C to 70°C)
Operating humidity
5% to 85% non-condensing
Non-operating humidity
5% to 90%, non-condensing with a maximum wet bulb of 82
o
F (28
o
C) at temperatures from
77°F to 95°F (25°C to 35°C)
Altitude
0ft (sea level) to 6000 ft (0 to 1800 m)