Firepower 7000 and 8000 Series Installation Guide
Chapter 6 Using the LCD Panel on a Firepower Device
Error Alert Mode
When a hardware error alert occurs, the LCD displays the main hardware alert menu, as follows:
HARDWARE ERROR!
Exit
You can use the multi-function keys to scroll through the list of error alerts or exit Error Alert mode.
Note that the LCD display continues to flash and display an alert message until all error conditions are
resolved.
The LCD panel always displays the platform daemon error message first, followed by a list of other
hardware error messages. The following table provides basic information on Firepower device error
messages, where
X
indicates the NFE accelerator card (
0
or
1
) that generated the alert.
Table 6-5
Hardware Alarm Error Messages
Error Message
Condition Monitored
Description
NFE_platformd
X
platform daemon
Alerts when the platform daemon fails.
NFE_temp
X
temperature status
Alerts when the temperature of the accelerator card exceeds
acceptable limits:
•
WARNING
: greater than 80°C/176°F (7000 Series) or 97°C/206°F
(8000 Series).
•
CRITICAL
: greater than 90°C/194°F (7000 Series) or
102°C/215°F (8000 Series).
HeartBeat
X
heartbeat
Alerts when the system cannot detect the heartbeat.
frag
X
nfe_ipfragd
(host frag)
daemon
Alerts when the
ipfragd
daemon fails.
rules
X
Rulesd
(host rules) daemon
Alerts when the
Rulesd
daemon fails.
TCAM
X
TCAM daemon
Alerts when the
TCAM
daemon fails.
NFEMessD
X
message daemon
Alerts when the message daemon fails.
NFEHardware
hardware status
Alerts when one or more accelerator cards is not communicating.
NFEcount
cards detected
Alerts when the number of accelerator cards detected on the device
does not match the expected accelerator card count for the platform.
7000 Series only:
GerChr_comm
8000 Series only:
NMSB_comm
communications
Alerts when the media assembly is not present or not
communicating.
7000 Series only:
gerd
8000 Series only:
scmd
scmd
daemon status
Alerts when the
scmd daemon
fails.
7000 Series only:
gpsl
8000 Series only:
psls
psls
daemon status
Alerts when the
psls daemon
fails.