7-6
Firepower 7000 and 8000 Series Installation Guide
Chapter 7 Hardware Specifications
Firepower 7000 Series Devices
Firepower 7110 and 7120
The Firepower 7110 and 7120 devices, part of the 71xx Family, are 1U appliances, and are delivered
with eight copper or eight fiber interfaces, each with configurable bypass capability. See the
Regulatory
Compliance and Safety Information for FirePOWER and FireSIGHT Appliances
document for safety
considerations for 71xx Family appliances.
Table 7-9
Firepower 70xx Family Physical and Environmental Parameters
Parameter
Description
Form factor
1U, half rack width
Dimensions (D x W x H)
Single chassis: 12.49 in. x 7.89 in. x 1.66 in. (31.74 cm x 20.04 cm x 4.21 cm)
2-Chassis Tray: 25.05 in. x 17.24 in. x 1.73 in. (63.62 cm x 43.8 cm x 4.44 cm)
Chassis weight
maximum installed
Chassis: 7 lbs (3.17 kg)
Single chassis and power supply in tray: 17.7 lbs (8.03 kg)
Double chassis and power supplies in single tray: 24.7 lbs (11.2 kg)
Copper 1000BASE-T
Gigabit copper Ethernet bypass-capable interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Power supply
200 W AC power supply
Voltage: 100 VAC to 240 VAC nominal (90 VAC to 264 VAC maximum)
Current: 2A maximum over the full range
Frequency range: 50/60 Hz nominal (47 Hz to 63 Hz maximum)
Operating temperature
7010/20/30
32°F to 104°F (0°C to 40°C)
7050
23°F to 104°F (-5°C to 40°C)
Non-operating temperature 7010/20/30
-4°F to 158°F (-20°C to 70°C)
7050
14°F to 140°F (-10°C to 60°C)
Operating humidity
7010/20/30
5% to 95%, non-condensing
Operation beyond these limits is not guaranteed and not recommended.
7050
5% to 85%, non-condensing
Operation beyond these limits is not guaranteed and not recommended.
Non-operating humidity
7010/20/30
0% to 95%, non-condensing
7050
0% to 85%, non-condensing
Store the unit below the maximum non-condensing relative humidity. Acclimate below
maximum operating humidity at least 48 hours prior to placing the unit in service.
Altitude
0 ft (sea level) to 5905 ft (0 m to 1800 m)
Cooling requirements
682 BTU/hour
You must provide sufficient cooling to maintain the appliance within its required operating
temperature range. Failure to do this may cause a malfunction or damage to the appliance.
Acoustic noise
53 dBA when idle. 62 dBA at full processor load
Operating shock
No errors with half a sine wave shock of 5G (with 11 ms duration)
Airflow
20 ft
3
(0.57 m
3
) per minute
Airflow through the appliance enters at the front and sides and exits at the rear.