Chapter 4 Turn Up a Network
Before You Begin
NTP-H28 Point-to-Point Network Acceptance Test
Step 1
Complete the
“DLP-H29 Log into CTC” task on page 16-43
at one of the point-to-point nodes. If you
are already logged in, continue with Step 2.
Step 2
From the View menu choose
Go to Network View
.
Step 3
Click the
Alarms
tab and click Synchronize.
a.
Verify that the alarm filter is not on. See the
“DLP-H88 Disable Alarm Filtering” task on
as necessary.
b.
Verify that no unexplained alarms appear on the network. If alarms are present, investigate and
resolve them before continuing. Refer to the
Cisco ONS 15310-MA SDH Troubleshooting Guide
if
necessary.
c.
Complete the
“DLP-H223 Export CTC Data” task on page 18-20
to export the alarm data to a file.
Step 4
On the
Conditions
tab, and click Retrieve.
a.
Verify that the network does not have any unexplained conditions. If unexplained conditions are
present, resolve them before continuing. Refer to the
Cisco ONS 15310-MA SDH Troubleshooting
Guide
if necessary.
b.
Complete the
“DLP-H223 Export CTC Data” task on page 18-20
to export the condition data to a
file.
Step 5
On the network map, double-click a point-to-point node to open it in node view.
Step 6
Create a test circuit from the login node to the other point-to-point node:
•
For E1 circuits, complete the
“NTP-H37 Create an Automatically Routed E1 Circuit” procedure on
. When you set the circuit state, choose
unlocked
and check the
Apply to drop ports
check
box.
•
For DS3/E3 circuits, complete the
“NTP-H40 Create an Automatically Routed DS-3 or E3 Circuit”
. When you set the circuit state, choose
unlocked
and check the
Apply to
drop ports
check box.
•
For optical circuits, complete the
“NTP-H47 Create an Automatically Routed Optical Circuit”
. When you set the circuit state, choose
unlocked
and check the
Apply to
drop ports
check box.
Step 7
For the ONS 15310-MA SDH, configure the test set for the test circuit type you created:
•
Wideband Electrical ports (WBE) E1—On the ONS 15310-MA SDH, if you are testing an unmuxed
E1, use the Champ connectors on the BICs on the rear of the chassis. Set the test set for E1. For
information about configuring your test set, consult your test set user guide.
Purpose
This procedure tests two ONS 15310-MAs in a point-to-point network.
Tools/Equipment
Test set/cables appropriate to the test circuit you will create
Prerequisite Procedures
NTP-H27 Provision a Point-to-Point Network, page 4-3
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
Provisioning or higher
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...